Service manual
2 - 22
PQV-TL
B
R
PQV-TR
PQV-BL
PQV-BR
PQV (Top Left)
Adjust to 0.3mm or less.
Adjust to 0.3mm or less.
Adjust to 0.3mm or less.
Adjust to 0.3mm or less.
PQV (Top Right)
PQV (Bottom Left)
PQV (Bottom Right)
4V-COIL
10
11
12
13
Adjustment item name
Problem Adjustment point Adjustment procedure
Adjustment
order
* Specify the adjustment value range of the following adjustment items in general DDCP
adjustment.
Adjustment items Adjustment value range (Factory mode))
CONVERGENCE (HOR.) 2Bh (43) - D3h (211) (OSM display value=DAC output value)
CONVERGENCE (VER.) 47h (71) - B7h (183) (OSM display value=DAC output value)