Service manual

2 - 29
2.5.1.10 Adjustment value list
The horizontal width, vertical width and DBF-H/V amplitude must be within the following ranges.
Timing
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Adj. value
396±5
396±5
396±5
396±5
396±5
396±5
396±5
396±5
Adj. value
297±4
297±4
297±4
297±4
297±4
297±4
297±4
297±4
297±4
Standard Adj. value
400±5
400±5
400±5
400±5
400±5
400±5
400±5
400±5
400±5
Max. Adj. value
430
430
430
430
430
430
430
430
430
Standard Adj. value
135±20
135±20
135±20
135±20
135±20
135±20
135±20
135±20
135±20
Max. Adj. value
200
200
200
200
200
200
200
200
200
Horizontal width (mm) Vertical width (mm)
DBF-H amplitude (H) DBF-V amplitude (V)
Standard adjustment value: in case of determining DBF voltage
Maximum adjustment value: the value impossible to set the maximum of DBF voltage
396±5