2.6 DDC function, check of asset management
This writing operation should be carried out with the service tool (refer to the followings for
detail of service tool).
The version of the service tool software used is as follows.
Service tool S/W folder name: SVT312NM210
Service tool S/W version: Ver3.12-2.1-0
Be sure to read Read me first first in using the service tool.
For concrete use, refer to the service tool manual attached to the service tool.
MPU side          Dedicated EEPROM side      Data (H)
Address (H)        Address (H)
Lower 5 digits of S/N → converted to hex. Numbers → registered in ascending order
Upper 3 digits of S/N → 0 (according to VESA standard)
(Ex.) 512002978 → 00000BA2 → Models having
MPU side       Dedicated EEPROM side  Data (H)
Address (H)       Address (H)
NO ASSET function  ASSET function
Models having
  
[ASCII conversion]
Using the barcode system read the serial numbers (9 digits) assigned at NMV (Nagasaki), then establish the serial
number through the following conversion.
S/N → converted to ASCII code → registered (to Monitor Descriptor #4) in descending order
(ex.) 512A02978
35 31 32 41 30 32 39 37 38
Models having        Models having
NO ASSET function     ASSET function
78C            0C A2
78D 0D 0B
78E           0E 00
78F 0F 00
E81            71              35
E82            72              31
E83            73              32
E84            74              41
E85            75              30
E86            76              32
E87            77              39
E88            78              37
E89            79              38
E8A           7A              0A → shows the end of S/N data*
E8B           7B              20 → shows blank*
E8C           7C 20 → shows blank*
E8D           7D 20 → shows blank*
         
                 *Fixed data (set according to the number of digits of S/N)