Specifications

APPENDIX 3 CABLE MANUFACTURING DRAWINGS
Appendix 3.1 FCUA-R000 Cable Manufacturing Drawing
I-25
Appendix 3.1 FCUA-R000 Cable Manufacturing Drawing
Application: Remote I/O unit (FCU6-DX561) to spindle connection
Option (compatible connector set)
FCUA-CS000
Assembly drawing
1 2
3
1 2
R000
Note
(
3
)
R000
Connection diagram
Max. cable length: 30m
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
Case GND plate
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
Case GND plate
Remote I/O unit side
ENC1/ENC2
Spindle amplifier side
CN8
Manufacturing precautions
(1) The wire material shall be a shielded, 10-pair stranded cable equivalent to UL20276 Standard
AWG28 (0.08mm
2
).
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(4) Fold the wire material shield over the sheath, and wrap copper foil tape over it. Then clamp with
the connector case frame.
(5) Part No. 1 (connector) and part No. 2 (connector case) are solderless types. If soldering types
are required, use parts 10120-3000VE for the connector and 10320-52F0-008 for the connector
case (both parts manufactured by Sumitomo 3M).
List of parts used
No. Part name/model Maker Qty.
1
Connector
10120-6000EL
Sumitomo 3M 2
2
Connector case
10320-3210-000
Sumitomo 3M 2
3
Wire material
UL20276
AWG28 × 10P
Note (1) (1)
(Note) This cable is the same as the SH21
cable.