Instruction manual
52
Recording (continued)
Setup Menu
  Emergency Recording Setup
This item  is used  to set  the emergency  recording  settings. 
When the  EMERGENCY terminal  is  grounded  by  the  alarm 
sensor  while  both  of  the  MAIN  switch  on  the  rear  panel 
and  the  POWER  button on the front  panel  are  turned  ON, 
emergency  recording  starts automatically overriding all  the 
other  settings  even  during  timer recording  or the unit  is in 
stop mode.
 Emergency  recording  is  not performed while  the  MAIN 
switch  or  POWER  button is  turned  OFF or  while  timer 
recording stand-by mode.
 The setting of the <Recording> menu cannot be changed 
during  normal recording  or alarm recording. To  change 
setting  during  recording,  stop  recording  in  case of 
normal recording.  In  case of  alarm  recording, when  the 
“Alarm  Input” in  the  <Recording> menu is  set  to  “Off,” 
the alarm input is not accepted for 5 minutes. When you 
stop recording during this time, the setting change of the 
<Recording> menu is available.
Recording1
5
D
Setup Menu
Emergency Recording Setup
Emergency Record Settings
[Recording]
step
1.  Select the frame or field recording.
step
2.  Set the long pre-alarm recording time in “Pre-alarm 
Duration.”
  0  min:  Does  not  execute  the  long  pre-alarm 
recording.
step
3.  Set  the  emergency  recording time  in “Post-alarm 
Duration.”
step
4.  Set the maximum recording rate.
[Camera Setting]
step
5.  Set the recording camera.
•  The button  function  changes  between “All  Off” 
and “All On” each time you select this button.
step
6.  Select “Execute.”
•  The preview screen appears.
  Emergency recording
1)  The picture grade  is “L6-30KB” and  the  recording  rate 
is set to  the  value obtained  by  dividing  the  maximum 
emergency  recording rate by the number  of  specified 
cameras.
 When  the  LPA  area  is  set  in  the  main  device,  the 
emergency  recording  data  is  stored  in  the  LPA area 
and is  automatically locked in  512 MB unit  including  the 
emergency recording data in order to prevent overwriting 
the data.
In LPA area, the data is always recorded at the rate set for 
alarm recording regardless of an input of the emergency 
signal. Therefore,  when  the  emergency  recording  is 
started  from  the  mid-part  of  the  data  block,  the  data 
recorded before the ground of the EMERGENCY terminal 
is  stored  in  the  locked area  along with  the  emergency 
recording.
 When you set the long pre-alarm recording time without 
setting the LPA area, long pre-alarm recording  is carried 
out using the internal memory for pre-alarm recording, so 
long pre-alarm  recording  is  performed for  the  short  time 
period regardless of the setting.
 When emergency  recording is carried out using  the LPA 
area,  data is  not  stored  chronologically and  alarms  are 
listed out of sequence. Be careful when searching for the 
desired picture.
 When power failure  occurs  during  emergency  recording, 
the emergency recording is cancelled after returning from 
the power failure.
 When  emergency recording is  carried  out  during timer 
recording, the end time of the timer recording is extended 
until the  emergency  recording  is completed.  The  timer 
recording  is finished after  completing the  emergency 
recording.
2) 
Cameras to be used
  Cameras which are set in <Emergency Recording Setup> 
are used.
3) 
During emergency recording:
•  “E-REC” is displayed on the screen in red. 
•  The  camera  number  buttons  and  camera  number dis-
p
lay  on  the  screen  which are  used  for  emergency  re-
cording fl
ash.
4)  Emergency  recording  is  registered  in  the alarm list  and 
displayed in magenta.