Instruction manual
40
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
<INITIAL SET UP/INFORMATION> (continued)
Setting ( default : “REMAIN” )
“REMAIN”, “WARNING”, “ALARM”, “OFF”
SETTING
BUZZER
When reaching the remaining
capacity set in “REMAIN HDD”
When a failure occurs and
a warning is displayed
When an alarm recording or
emergency recording is started
REMAIN
ON
OFF
OFF
WARNING
OFF
ON
OFF
ALARM
OFF
OFF
ON
OFF
OFF
OFF
OFF
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “BUZZER” in the <RAR
TERMONAL SETTINGS> screen. Display the desired setting
and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
♦ REMAIN HDD
A warning indicating that the remaining HDD capacity has
become low during recording is outputted. The remaining
capacity for this warning is set here.
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
KEY SOUND ON
BUZZER REMAIN
>>
REMAIN HDD HDD-10
%
CALL OUT SETTINGS
EMERGENCY REC DURATION 10M
A warning is outputted using the following meth-
ods when the remaining capacity becomes low dur-
ing recording.
• The HDD USAGE display flashes when “3” is set
to “DISPLAY MODE” in the <TIME DATE DISPLAY>
screen.
• A buzzer will sound when “REMAIN” is set to
“BUZZER” in the <REAR TERMINAL SETTINGS>
screen.
Setting of “DEVICE” ( default : “HDD” )
“
HDD” : Displays a warning of low HDD capacity.
“OFF” : Does not display warning of low HDD ca-
pacity.
Setting of “REMAIN HDD” ( default : “10%” )
“2%”, “4%”, “6%”, “8%”, “
10%”, “15%”,“20%”, “30%”,
“40%”, “50%”
1. Select the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
“REMAIN HDD” in the <REAR
TERMINAL SETTINGS> screen and turn the SHUTTLE ring
clockwise twice.
• The “PPS” setting display reverses in color when the
SHUTTLE ring is turned the first time. When the ring is turned
for the second time, the background turns red and flashes.
2. Turn the JOG dial to display the desired device and turn the
SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
3. Turn the JOG dial clockwise to move the reversed display
to the REMAIN HDD value and turn the SHUTTLE ring
clockwise.
• The background of the REMAIN HDD value turns red and
flashes.
4. Turn the JOG dial to display the desired capacity and turn
the SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
5. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
♦ CALL OUT SETTINGS
The CALL OUT setting is a setting to notify to the outside
warning signals outputted by this device by outputting the
signals from the CALL OUT terminal on the rear.
• HDD REMAIN
When reaching the set remaining HDD capacity, a signal is
outputted from the CALL OUT terminal and “CAPACITY
REMAIN WARNING” is displayed.
<CALL OUT SETTINGS>
>>
HDD REMAIN OFF
HDD FULL OFF
Setting ( default : “OFF” )
“2%”, “4%”, “6%”, “8%”, “10%”, “15%”,“20%”, “30%”,
“40%”, “50%”, “OFF”
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
<REAR TERMONAL SETTINGS>
}
Select “HDD REMAIN” in the <CALL OUT SETTINGS>
screen. Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
By pressing the WARNING RESET button, the
HDD capacity warning from the CALL OUT terminal
can be canceled.
INFORMATION
For the relationship of the warning display and CALL
OUT signal output, see page 87. Although the
warning will be displayed regardless if the output
item for the CALL OUT signal is set to “FIXED”, the
condition to output CALL OUT signals can be added
when the output is set to “SELECT”. For example,
the buzzer can be set to sound when reaching a
value set in “HDD REMAIN WARNING” of the <CALL
OUT SETTINGS> screen if “BUZZER” in the <REAR
TERMINAL SETTINGS> screen is set to “WARN-
ING”.