Instruction manual

41
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Operations
ENGLISH
HDD FULL
When the recordable HDD space becomes empty, a sig-
nal is outputted from the CALL OUT terminal and a REC
FULL warning is displayed.
<CALL OUT SETTINGS>
HDD REMAIN OFF
>>
HDD FULL OFF
Setting of device ( default : OFF )
ON : Signal is outputted when the recording ca-
pacity becomes empty.
OFF : No signal is outputted when the recording
capacity becomes empty.
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
<REAR TERMONAL SETTINGS>
}
Select HDD FULL in the <CALL OUT SETTINGS> screen.
Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
EMERGENCY REC DURATION
The recording time for alarm recording can be set.
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
KEY SOUND ON
BUZZER REMAIN
REMAIN HDD HDD-10
%
CALL OUT SETTINGS
>>
EMERGENCY REC DURATION 10M
For details concerning setting EMERGENCY
RECORDINGS,
see page 48.
Setting ( default : 10M )
1M, 2M, 5M,
10M, 20M, 30M, 60M
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL
SET UP/INFORMATION>
}
Select EMERGENCY REC
DURATION in the <REAR TERMONAL SETTINGS> screen.
Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
RS-232C
Settings for the communication device connected to this
unit is set.
MODE
This unit can be remote controlled from a PC connected to
the RS-232C terminal. Comments can also be inputted from
a PC for recording of comments along with the video (
see pages 60-81).
<RS-232C>
>>
MODE REMOTE A
SETTINGS
Setting ( default : REMOTE A )
REMOTE A : This unit can be controlled from a
PC and status condition change information is re-
turned from the unit.
REMOTE B : This unit can be controlled from a
PC and status condition change information is not
returned from the unit.
OFF : This unit cannot be controlled from a PC.
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL
SET UP/INFORMATION>
}
Select MODE in the <RS-232C>
screen. Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
RS-232C SETTINGS
RS-232C settings can be made when setting MODE
above to REMOTE A or REMOTE B.
<RS-232C SETTINGS>
>>
TRANSMISSION MODE 1200
DATA BIT LENGTH 8BIT
PARITY BIT NONE
STOP BIT LENGTH 1BIT
DELIMITER CR
!
Perform settings so that the settings are the same
with the connecting PC.
Setting of TRANSMISSION MODE ( default :
1200 )
1200, 2400, 4800, 9600, 19200
Setting of DATA BIT LENGTH ( default : 8BIT )
8BIT, 7BIT
Setting of PARITY BIT ( default : NONE )
NONE, ODD, EVEN
Setting of STOP BIT LENGTH ( default : 1BIT )
1BIT, 2BIT
Setting of DELIMITER: ( default : CR )
CR, CRLF
1. Set RS-232C MODE to REMOTE A or REMOTE B.
2. Select SETTINGS and turn the SHUTTLE ring clockwise.
The <SETTINGS> screen appears.
3. Select the setting to change and turn the SHUTTLE ring
clockwise.
The background of the setting turns red and flashes.