Instruction manual

46
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Operation examples (continued)
7) <TIMER PROGRAM> screen setting ( see pages
34, 35 ).
SPL : MON - FRI.
PROGRAM NO.1 : SPL, 08:00, 15:00, A, OFF.
PROGRAM NO.2 : SPL, 15:00, 20:00, B, OFF.
PROGRAM NO.3 : SAT, 08:00, 17:00, B, OFF.
PROGRAM NO.4 : SUN, 08:00, 17:00, B, OFF.
PROGRAM NO.5 : HOL, 08:00, 17:00, B, OFF.
<TIMER PROGRAM> P1
DW START END MODE M-DET
>>
1 SPL 08:00 15:00 A OFF
2 SPL 15:00 20:00 B OFF
3 SAT 08:00 17:00 B OFF
4 SUN 08:00 17:00 B OFF
5 HOL 08:00 17:00 B OFF
6 --- --:-- --:-- ---- ---
7 --- --:-- --:-- ---- ---
8 --- --:-- --:-- ---- ---
SPL MON-FRI
When completed with all settings above and after clear-
ing the menu screen, press the TIMER button. The unit
will switch to the timer mode.
Operation example 3
This example uses a combination of normal recording, pre-
alarm recording, alarm recording and emergency record-
ing.
< Operation >
REC MODE C (pre-alarm recording, alarm recording and
emergency recording with all cameras) is set to Monday ~
Friday from 08:00 to 15:00 and REC MODE D (pre-alarm
recording, alarm recording and emergency recording with
camera number
1
,
2
,
3
,
7
,
8
and
9
) is
set to 15:00 ~ 08:00 of the following day.
On weekends, REC MODE D (pre-alarm recording, alarm
recording and emergency recording with camera number
1
,
2
,
3
,
7
,
8
and
9
) is set to 08:00 ~
08:00 of the following day.
Next day
08:00
Next day
08:00
REC MODE C
REC MODE D
REC MODE D
From Monday
to Friday
Saturday and
Sunday
08:00
08:00
15:00
< Setting >
1) Set 1) ~ 3) of Operation example 1 above.
2) <REAR TREMINAL SETTNIGS> screen setting (
see page 41).
EMERGENCY REC DURATION : 20M.
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
KEY SOUND ON
BUZZER REMAIN
REMAIN HDD HDD-10
%
CALL OUT SETTINGS
>>
EMERGENCY REC DURATION 20M
3) Set each item in the <MOTION DETECTION SET-
TINGS> screen for all cameras ( see pages 29-31).
SELECTION CAMERA NUMBER, MOTION DETECTION
: Set operation to ON or OFF for all cameras.
1
<MOTION DETECTION SETTINGS>
>>
SELECTION CAMERA NUMBER
MOTION DETECTION OFF
DETECTION MASK SETTING
SENSITIVITY HIGH••<<<LOW
MOTION THRESHOLD 1
TEST MODE
4) <TIMER PROGRAM SETTINGS> screen setting (
see pages 35, 36).
SELECTED PATTERN : P3.
REC MODE C : PRE ALARM.
REC MODE D : PRE ALARM.
ALARM REC DURATION : 5M.
PRE ALARM REC : MEDIUM.
<TIMER PROGRAM SETTINGS>
SELECTED PATTERN P3-SET
HOLIDAY SETTING
REC MODE A NORMAL
&
ALARM-SET
REC MODE B NORMAL
&
ALARM-SET
REC MODE C PRE ALARM-SET
REC MODE D PRE ALARM-SET
ALARM REC DURATION 5M
>>
PRE ALARM REC MEDIUM
5) <REC MODE C> screen setting ( see pages 35, 36 ).
Camera selectoin during alarm recording : ALL.
All cameras (
1
~
9
)
PPS, GRADE, A-PPS, A-GRADE : Set desired interval
and picture quality for each camera.
9
7
4
5
6
1
2
3
8
<REC MODE C> ALL
NO.PPS GRADE A-PPS A-GRADE
>>
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
1.39F STD 1.39F HIGH
<ESTD TIME> H M
6) <REC MODE D> screen setting ( see pages 35,
36).
Camera selectoin during alarm recording : ALL.
Camera number
1
,
2
,
3
,
7
,
8
and
9
only.
PPS, GRADE, A-PPS, A-GRADE : Set desired interval
and picture quality for each camera.
Other camera.
PPS, A-PPS : - - - - -.
9
7
4
5
6
1
2
3
8
<RECORD SETTING D> ALL
NO.PPS GRADE A-PPS A-GRADE
>>
2.08F SUPER 4.17F HIGH
2.08F SUPER 4.17F HIGH
2.08F SUPER 4.17F HIGH
----- STD ----- STD
----- STD ----- STD
----- STD ----- STD
2.08F STD 4.17F HIGH
2.08F SUPER 4.17F HIGH
2.08F SUPER 4.17F HIGH
<ESTD TIME> H M