Various search (continued)
<ALARM SKIP SEARCH>
>>
EXECUTE(FORWARD)
EXECUTE(REVERSE)
PUSH SEARCH KEY FOR
SEARCH SELECTION
7. To clear the search screen, press the SEARCH button.
!
To change the desired camera number to the single screen display during still-
frame playback in SPLIT9 display, press the SEARCH button to clear the search
setting screen and press the desired camera number button.
!
Search may not perform properly at times depending on the recorded condition
of the index signals.
■ SKIP SEARCH
It is possible to forward/reverse to locations where index signals of alarm re-
cordings are recorded and play back approximately 4 seconds of each video.
<SKIP SEARCH> In the case of forward direction
SKIP COUNT
0302
01
Alarm
Recording
Alarm
Recording
Alarm
Recording
Index signalIndex signalIndex signal
Forward ForwardForward Forward
Present position
Approx. 4 sec.
palyback
Approx. 4 sec.
palyback
Approx. 4 sec.
palyback
1. Press the SEARCH button.
• The search screen selected in above “SEARCH TYPE” appears.
2. (When the desired search screen is not displayed on the screen • • • )
Change the above “SEARCH TYPE” setting and display the “SKIP SEARCH”
screen.
3. Select “EXECUTE(FORWARD)” or “EXECUTE(REVERSE)” and confirm.
• “EXECUTE(FORWARD)” : Search is performed in the forward direction.
• “EXECUTE(REVERSE)” : Search is performed in the reverse direction.
• To cancel the search, press the SEARCH button.
• Playback of search result from skip search will be in SPLIT9 display regardless of
whether the above “SELECTION CAMERA NO.” is set to “ALL” or individual camera
number is selected.
• To return to the normal screen, press the SEARCH button.
!
The unit cannot be changed to single screen display mode during playback in
SPLIT9 dispaly.
4. Press the PLAY button when the desired video is displayed.
• Playback will continue without forwarding/reversing.
5. To stop SKIP SEARCH, press the STOP button.
6. To clear the search screen, press the SEARCH button.
!
When performing skip search in the reverse direction with index
signals of less than 4 seconds, that portion may play back repeatedly.
In this case, press the PLAY/STOP button to stop the search and per-
form skip search in the reverse direction again after the particular por-
tion has been passed using reverse playback, etc.
!
Search may not perform properly at times depending on the re-
corded condition of the index signals.
■ ALARM LIST SEARCH
This unit stores the start time of alarm recording and emergency recording in
the alarm list when such recording begins. It is also possible to index search
the desired time (or the closest time) from the list of alarm recording (emer-
gency recording) start times stored in the alarm list.
Up to 10,000 alarm recording (emergency recording) start times
can be stored and displayed.