Specifications
Specifications
Rated Power Supply: AC 100-240V 50/60Hz
Rated Input: 1.0 - 0.5A (100-240V)
Color System: PAL-type color system.
Operating Temperature: 41°F-104°F (5°C to 40°C).
Relative Humidity: Max.80(%)
Altitude: Max.2000(m)
Dimensions: 300(Width) x 350(Depth) x 88(Height)(mm).
Weight: 5.0kg
Recording System Digital recording method using WAVELET compression.
Sampling 13.5MHz
Data Compression WAVELET
Compression Unit Field
Resolution 684 x 244
Recording Device 80GB HDD
Video Input: 9 Input BNC-Connector: 1.0 V(p-p), 75 ohms.
Monitor Output: S-Connector: Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.286 V(p-p), 75 ohms.
BNC-Connector: 1.0 V(p-p), 75 ohms.
Throughout Output: 9 Output BNC-Connector: 1.0 V(p-p), 75 ohms.
Audio Input: -8 dBs, 50 kohms.
Audio Output: -8 dBs, 1 kohms.
Microphone Input: -67 dBs, 600 ohms.
Timer Program: 8programs-Daily start and stop time for one week x 3set.
Memory Backup: Lasts for more than 1 month.
CONNECTORS
ALARM IN(1-9) Input: Terminal for starting alarm recording.
CLOCK ADJ Input: Terminal for adjusting clock.
REC Input: Terminal for start recording.
EMERGENCY Input: Terminal for start emergency recording.
GND: Terminal for ground.
MODE OUT(1-4) Output: Terminal for indication of recording selected mode.
DC 5V OUT Output: Terminal for DC 5V OUT.
CALL OUT/CALL OUT GND: Terminal for external warning device.
Rating:
MODE OUT(1-4) Active: “Low” Level. Max. Drive current 7mA DC.
Non active: Open. Max. Voltage +24V DC.
ALARM IN / CLOCK ADJ / Active: When terminals are short-circuited
REC/EMERGENCY or “Low” Level voltage is applied.
Non active: Open.
CALL OUT / Active: ON. Max. Drive current 7mA DC.
CALL OUT GND Non active: Open. Max. Voltage +24V DC.
RS-232C RS-232C (D-SUB 9pin) terminal for connection with personal computer.
Accessories
AC power cord (for U.K / for the Continent) 2
Compact Flash cover (mounted on unit) 1
Compact Flash Card recording format Original format (FSM1)
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
<Interface circuit inside the unit>
5V
5V
10kΩ
22kΩ
Input
terminal
0.047µF
GND
EMERGENCY/ALARM IN/REC/
CLOCK ADJ Input terminal
• Input Circuit
<Interface circuit inside the unit>
Output terminal
GND terminal
MODE OUT 1 - 4 Output terminal
• Output Circuit
<Interface circuit inside the unit>
CALL OUT terminal
CALL OUT GND terminal
CALL OUT output terminal
• Output Circuit