HARDWARE MANUAL [CONNECTION] GOT-F900 SERIES GRAPHIC OPERATION TERMINAL Covered models Screen creation software F920GOT-K F920GOT-BBD-K-E F920GOT-BBD5-K-E GT Designer2 (SW*D5C-GTD2-E) F930GOT(-K) F930GOT-BWD-E F930GOT-BBD-K-E GT Designer (SW*D5C-GOTR-PACKE) FX-PCS-DU/WIN-E F940GOT F940WGOT-TWD-E F940GOT-SWD-E/-LWD-E Handy GOT F940GOT-SBD-H-E/-LBD-H-E F943GOT-SBD-H-E/-LBD-H-E F940GOT-SBD-RH-E/-LBD-RH-E F943GOT-SBD-RH/-E-LBD-RH-E
GOT-F900 SERIES (CONNECTION) Foreword • This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the GOT-F900 SERIES GRAPHIC OPERATION TERMINAL. It should be read and understood before attempting to install or use the unit. • Further information can be found in the GOT-F900 Operation Manual, F920GOT-K Installation Manual, F930GOT Installation Manual, F930GOT-K Installation Manual, F940GOT Installation Manual, F940WGOT Installation Manual.
GOT-F900 SERIES (CONNECTION) GOT-F900 SERIES GRAPHIC OPERATION TERMINAL HARDWARE MANUAL (CONNECTION) Manual number : JY992D94801 Manual revision : C Date : MARCH 2003 i
GOT-F900 SERIES (CONNECTION) ii
GOT-F900 SERIES (CONNECTION) FAX BACK Mitsubishi has a world wide reputation for its efforts in continually developing and pushing back the frontiers of industrial automation. What is sometimes overlooked by the user is the care and attention to detail that is taken with the documentation. However, to continue this process of improvement, the comments of the Mitsubishi users are always welcomed. This page has been designed for you, the reader, to fill in your comments and fax them back to us.
GOT-F900 SERIES (CONNECTION) iv
GOT-F900 SERIES (CONNECTION) Guidelines for the Safety of the User and Protection of the Graphic operation terminal GOT-F900 This manual provides information for the use of the Graphic operation terminal GOT-F900. The manual has been written to be used by trained and competent personnel.
GOT-F900 SERIES (CONNECTION) • Under no circumstances will Mitsubishi Electric be liable responsible for any consequential damage that may arise as a result of the installation or use of this equipment. • All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
Contents GOT-F900 SERIES (CONNECTION) Guidelines .............................................................................................................. v 1. Introduction .....................................................................................................1-1 1.1 Rank and Use Method of This Manual ................................................................ 1-1 1.1.1 Classification of Manuals in Accordance with Purpose ............................................. 1-3 1.
Contents GOT-F900 SERIES (CONNECTION) 5. Installation and Wiring of Handy GOT ............................................................5-1 5.1 Outline of Connection .......................................................................................... 5-5 5.1.1 Handy GOT (Excluding RH model) ........................................................................... 5-5 5.1.2 Handy GOT (RH model) ............................................................................................ 5-7 5.
Contents GOT-F900 SERIES (CONNECTION) 6. Connection of Peripheral Equipment (Screen data transfer/Sequence program transfer and monitor) ....................6-1 6.1 Outline of Connection .......................................................................................... 6-1 6.2 Connection to Personal Computer ...................................................................... 6-3 6.2.1 Screen Data Transfer ..........................................................................................
Contents GOT-F900 SERIES (CONNECTION) 9. Connection of MELSEC-A Series PLC ...........................................................9-1 9.1 System Condition ................................................................................................ 9-2 9.2 System Configuration .......................................................................................... 9-2 9.2.1 Configuration for Direct Connection (RS-422)........................................................... 9-3 9.2.
Contents GOT-F900 SERIES (CONNECTION) 12.Connection of FX Series Positioning Unit (FX(2N)-10/20GM).......................12-1 12.1 System Condition .............................................................................................. 12-1 12.2 System Configuration ........................................................................................ 12-2 12.2.1 Configuration for GMCPU direct connection (RS-422)............................................ 12-2 12.
Contents GOT-F900 SERIES (CONNECTION) 14.6 Command Details ............................................................................................ 14-18 14.6.1 14.6.2 14.6.3 14.6.4 14.6.5 Batch Read Command .......................................................................................... 14-18 Batch Write Command .......................................................................................... 14-19 Bit-oriented Write Command ........................................................
Contents GOT-F900 SERIES (CONNECTION) 18.Connection of FP Series PLC (Manufactured by Matsushita Electric Works)18-1 18.1 System Condition .............................................................................................. 18-2 18.1.1 Classification of Product Names ............................................................................. 18-2 18.2 System Configuration ........................................................................................ 18-3 18.2.
Contents GOT-F900 SERIES (CONNECTION) 20.6 Caution on Use of SIMATIC S7-200/300/400 Series PLC .............................. 20-11 20.6.1 Restriction in devices depending on the model ..................................................... 20-11 20.6.2 Restriction in device specification ......................................................................... 20-11 20.7 Setting of Connected Equipment for GOT ....................................................... 20-12 20.8 Cable Diagram.................
Introduction 1 GOT-F900 SERIES (CONNECTION) Introduction Hardware manual (separate manual) [this manual] Handling of GOT and how to connect and set connected equipment Connected equipment - PLC by Mitsubishi - PLC by another manufacturer - Microcomputer board - Bar code reader GOT-F900 HARDWARE MANUAL [CONNECTION] (No.:JY992D94801) Manual packed together with GOT Handling of GOT (The contents described here are included in the manual above.
GOT-F900 SERIES (CONNECTION) Introduction 1 This manual describes how to set the screen creation software, select cables and perform wiring in connecting the GOT-F900 Series to a connected equipment. Information Offered by Model name and In-built Fonts ............................................................Introduction Outline of Connection Types ....................................................................................................... Section 1 Applicable PLC and connection type .......
GOT-F900 SERIES (CONNECTION) Introduction 1 Classification of Manuals in Accordance with Purpose When requiring a manual not included with the product, contact our sales representative. 2 COMMON HARDWARE MANUAL (sent separately) MODEL CODE 09R805 IIt is included as PDF data on CD-ROM of screen creation software SW"D5C-GTD2-E. It is included as PDF data on CD-ROM of screen creation software SW"D5C-GOTR-PACK.
GOT-F900 SERIES (CONNECTION) • F940GOT INSTALLATION MANUAL (No. JY992D94201) - To learn the features of the main unit. To confirm the specifications of the main unit. To learn the name of each part of the main unit. To learn how to install the main unit and wire the power supply. To look at the external dimensions diagram of the main unit. INSTALLATION MANUAL - It is included with the F940WGOT-TWD-E. F940 HANDY GOT HARDWARE MANUAL (No. JY992D86901) To learn the features of the main unit.
GOT-F900 SERIES (CONNECTION) Introduction 1 09R813 Two types of screen creation software are offered. The manual of the software you are using is required (It is included with the software.). GT Designer2 GT Designer2 (SW"D5C-GTD2-E) OPERATING MANUAL (separate manual) Consult with the distributor from which you have purchased GT Designer2. It is distributed as PDF data saved in the CDROM of the SW"D5CGTD2-E.
GOT-F900 SERIES (CONNECTION) • Introduction 1 FX-PCS-DU/WIN-E OPERATION MANUAL (No: JY992D68301) - To install the software to the personal computer. To start up the software. To learn how to connect the personal computer to the GOT. To learn the screen configuration of the software. To learn how to use the help function. MODEL CODE OPERATION MANUAL - It is included with the FX-PCS-DU/WIN-E.
GOT-F900 SERIES (CONNECTION) Introduction 1 Abbreviations, Generic Names and Terms Used in This Manual Abbreviations, generic names and terms used in this manual are shown below.
GOT-F900 SERIES (CONNECTION) 1.2.2 Introduction 1 Information Offered by Model Name GOT F9"""GOT-####-#-#-# 1) 2) 3) 4) 5) 6) 7) 8) 9) 1) LC display size 2: 3 in. 3: 4 in. 4: 6 in. (7 in.
GOT-F900 SERIES (CONNECTION) Introduction 1 In-built Fonts of Graphic Operation Terminal (Japanese/Overseas product) Carefully confirm the in-built fonts when selecting a model from the F920GOT-K or F930GOT(-K).
GOT-F900 SERIES (CONNECTION) 1.2.
GOT-F900 SERIES (CONNECTION) Introduction 1 Abbreviation/generic name/term PLC by PLC by another other company companies OS Description Generic name of PLC manufactured by Omron, Fuji Electric, Yasukawa Electric, Allen-Bradley or Siemens Abbreviation of GOT system software Introduction 1 2 Abbreviation of screen creation software for GOT-A900/GOT-F900 Series GT Designer GT Designer Others SW"D5CGTWORKS-E Integrated screen development software for GOT900 Series (SW"D5C-GOTRPACKE + GT Simulator) (E
GOT-F900 SERIES (CONNECTION) Introduction 1 Abbreviation/generic name/term Description BK Black W White Y Yellow BR Brown BL Blue GY Connection O diagram PL Gray PK Pink FGR Fresh green SB Sky blue R Red GR Green Orange Purple 1-12
Outline 2 GOT-F900 SERIES (CONNECTION) Outline This section describes the outline of PLC, bar code reader, printer, etc. which can be connected to the GOT-F900. The table below shows connection types supported by the GOT-F900 having the lastest OS version.
GOT-F900 SERIES (CONNECTION) 2.1.2 Outline 2 Connection type list and index "$" indicates can connect. "−" indicates cannot connect.
GOT-F900 SERIES (CONNECTION) Outline 2 This section describes the outline of connection of the GOT-F900 to the PLC manufactured by Mitsubishi. " indicates that a PLC programming tool (personal computer) can be connected. (Program transfer and monitoring are available using the programming software for the FX/A/QnA/Q Series.) FX Series PLC 1) CPU direct connection (RS-422) GOT-F900 is connected to the programming port of the FX Series PLC.
GOT-F900 SERIES (CONNECTION) Outline 2 2) CPU direct connection (RS-232C) By attaching the optional RS-232C communication board, a programming port can be added. As a result, the GOT-F900 or personal computer (for sequence programs) can be connected to each port. (A personal computer, printer or bar code reader can be connected only when the GOT is equipped with two RS-232C channels.
GOT-F900 SERIES (CONNECTION) Outline 2 1) CPU direct connection (RS-422) GOT-F900 is connected to the programming port of the A/QnA Series PLC or the motion controller. When a personal computer is connected to the GOT-F900, programs can be created. The serial communication unit of the Q/QnA Series PLC is connected through CPU direct connection. The GOT-F900 can be connected to only either one between two ports. (Connecting two GOT-F900 units to one serial communication unit is not allowed.
GOT-F900 SERIES (CONNECTION) Outline 2 3) A computer link connection GOT-F900 is connected to the A/QnA Series PLC by attaching the A CPU computer link unit. E ith e r o n e u n it*2 A c o m p u te r lin k u n it R S -4 2 2 o r R S -2 3 2 C C o m p u te r lin k u n it fo r M E L S E C - A S e r ie s P O W E R R S -2 3 2 C G O T -F 9 0 0 *1 P r in te r *1 Excluding the 5V type F920GOT-K. B a r c o d e re a d e r *2 Excluding the F920GOT-K.
GOT-F900 SERIES (CONNECTION) Outline 2 FREQROL Series CPU direct connection (RS-422) GOT-F900 is connected to the (built-in) PU port of the FREQROL Series inverter. In the A500 Series, the GOT-F900 can be connected also to the computer link option (FR-A5NR). Outline S ta tio n N o . 1 S ta tio n N o . 3 1 . . . . . . . . . . P O W E R In v e rte r In v e rte r 3 Specifications One GOT-F900 unit can control up to 10 inverters.
GOT-F900 SERIES (CONNECTION) Outline 2 PLC by Fuji Electric Link unit connection One GOT-F900 unit can be connected to the link unit of the FLEX-PC N Series (NB/NJ/NS) PLC.
GOT-F900 SERIES (CONNECTION) Outline 2 CPU direct connection (RS-232C) By connecting the HMI adapter to the SIMATIC S7-300 Series CPU, one GOT-F900 unit can be connected to the SIMATIC S7-300 Series CPU. By connecting the PC/PPI cable to the SIMATIC S7-200 Series CPU, one GOT-F900 unit can be connected to the SIMATIC S7-300 Series CPU. (A personal computer, printer or bar code reader can be connected only when the GOT is equipped with two RS-232C channels.
GOT-F900 SERIES (CONNECTION) Outline 2 MEMO 2-10
Specifications 3 GOT-F900 SERIES (CONNECTION) Specifications This section allows to confirm connectable equipment, device specifications, versions of applicable screen creation software and hardware specifications. There are following five types of OS. F940WGOT Remarks 940W system F940GOT, Handy GOT 940 system F930GOT 930 system F930GOT-K 930 system F920GOT-K 920 system The first product is Ver. 4.60 or later.
GOT-F900 SERIES (CONNECTION) 3.1.
GOT-F900 SERIES (CONNECTION) Specifications 3 Connection of two 940W 940 930 920 or more GOT units Reference system system system system Connection type name [QCPU direct connection] Connection to programming port in Q CPU Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU RS-232C 1.00 4.10 2.20 1.00 or later or later or later or later $*1 11.2.1 Q00JCPU,Q00CPU,Q01CPU RS-232C 1.30 6.30 4.30 1.00 or later or later or later or later $*1 11.2.
GOT-F900 SERIES (CONNECTION) 3.1.3 Specifications 3 PLC Manufactured by Other Companies The table below describes the product evaluated in each series.
GOT-F900 SERIES (CONNECTION) Specifications 3 Fuji Electric FLEX-PC N Series (link unit) RS-232C Connection type name [FLEX-PC N] 2 1.00 1.00 1.00 or later or later or later 16.2.2 RS-422 16.2.1 1.00 1.00 1.00 or later or later or later 1.00 5.00 3.00 or later or later or later 17.2.1 RS-422 RS-232C 1.00 5.00 3.00 or later or later or later 17.2.1 17.2.
GOT-F900 SERIES (CONNECTION) Connected equipment name and series name Specifications 3 RS-232C/ RS-422 OS version Connection of two Reference 940W 940 930 920 or more GOT units system system system system Allen-Bradly SLC500 Series (CPU direct connection) Connection type name [SLC500] Connection to port built in CPU SLC5/04 (1747-L541) RS-232C 1.00 2.00 2.00 1.
GOT-F900 SERIES (CONNECTION) Specifications 3 Version of Screen Creation Software and Correspondence to GOT-F900 Three types of screen creation software are offered the SW"DSC-GTD2-E, SW"D5C-GOTR-PACKE and FX-PCS-DU/WIN-E as follows.
GOT-F900 SERIES (CONNECTION) 3.2.1 Specifications 3 How to Conform Version of Screen Creation Software You can confirm the version by displaying the help screen after starting up the screen creation software in the personal computer or by confirming the contents indicated on the FD or CD-ROM of the product. 1) When confirming the version using the help function of the software For the GT Designer2, GT Designer and DU/WIN, you can confirm the version by selecting [Help (H)]-[About (A)] from the menu bar.
GOT-F900 SERIES (CONNECTION) Specifications 3 2) When confirming the version through the contents indicated on the media You can confirm the version by checking the contents indicated on the media of the product. a) GT Designer2 (CD-ROM) Introduction 1 2 MELSEC A version (An alphabet at the end indicates the small version.) 3 Specifications DATE 9812AA disc Outline MITSUBISHI MODEL SW1D5C-GTD2-E SW1D5C-GTD2-E "SW1" indicates the large version.
GOT-F900 SERIES (CONNECTION) 3.2.2 Specifications 3 Screen Creation Software Version Corresponding to GOT-F900 Series Japanese version "D5C-GTD2-J SW" Version "D5C-GOTR-PACK SW" Version FX-PCS-DU/WIN Version F940WGOT SW1-A (1.00A) SW5-F (5.05F) 2.50 F940GOT SW1-A (1.00A) SW1-A 2.00 F943GOT SW1-A (1.00A) SW1-A 2.00 F930GOT-K SW1-A (1.00A) SW5-26C (5.26C) − F930GOT SW1-A (1.00A) SW1-H 2.20 F933GOT SW1-A (1.00A) SW1-H 2.20 F920GOT-K (5V) SW1-A (1.00A) SW5-26C (5.26C) 2.
GOT-F900 SERIES (CONNECTION) Specifications 3 Screen Creation Software Corresponding to Each Connected Equipment Products in Japanese "D5C-GTD2-J SW" Version "D5C-GOTR-PACK SW" Version FX-PCS-DU/WIN Version SW1-A (1.00A) SW1-A 2.00 SW1-A (1.00A) SW2-A 2.30 SW1-A (1.00A) SW4-F 2.40 SW1-A (1.00A) SW5-P (5.13P) − SW1-A (1.00A) SW5-K (5.09K) 2.50 Microcomputer connection (general-purpose communication) SW1-A (1.00A) SW1-A SYSMAC C by Omron SW1-A (1.
GOT-F900 SERIES (CONNECTION) Specifications 3 Products in English Connected equipment (abbreviation) "D5C-GTD2-E SW" "D5C-GOTRSW" PACKE Version FX-PCS-DU/WIN-E Version SW1-E 2.00 SW2-A 2.30 SW4-F 2.40 SW5-P (5.13P) − SW5-K (5.09K) 2.50 Mitsubishi FXCPU direct connection SW1-C (1.02C) ACPU direct connection SW1-C (1.02C) A computer link SW1-C (1.02C) QnACPU direct connection SW1-C (1.02C) QnA computer link SW1-C (1.02C) QCPU direct connection SW1-C (1.
GOT-F900 SERIES (CONNECTION) Specifications 3 Devices in GOT-F900 The table below shows intrinsic devices built in the GOT-F900. Because these internal devices have no relevance to the devices in the connected PLC or the memory of the microcomputer board, they can be used without regard to the connected equipment.
GOT-F900 SERIES (CONNECTION) 3.3.
GOT-F900 SERIES (CONNECTION) Specifications 3 Device number representation Introduction 1 Hexadecimal 2 Setting range X0~X1FFF X0~X0FFF Output (Y) Y0~Y1FFF Y0~Y0FFF Internal relay (M) *1 M0~M8191 M0~M8191 Latch relay (L) *1 L0~L8191 L0~L8191 Annunciator (F) F0~F2047 F0~F2047 B0~B1FFF B0~B1FFF T0~T2047 Coil TC0~TC2047 Contact CT0~CT1023 Coil CC0~CC1023 − C0~C1023 Decimal − GOT internal bit register (GB) *2 GB132~1023 GB132~1023 Data register (D) D0~D8191 D0~D8191 Special
GOT-F900 SERIES (CONNECTION) Specifications 3 3) MELSEC-QnA/Q (Q mode) Series Setting range Device name GT Designer (2) Input (X) X0~X1FFF X0~X1FFF Output (Y) Y0~Y1FFF Y0~Y1FFF Internal relay (M) M0~M32767 M0~M32767 Hexadecimal Latch relay (L) L0~L32767 L0~L32767 Annunciator (F) F0~F32767 F0~F32767 Decimal Link relay (B) B0~B7FFF B0~B7FFF Special link relay (SB) SB0~SB7FF SB0~SB7FF TT0~TT32767 T0~T32767 Bit Timer (T) device Counter (C) Contact Coil TC0~TC32767 − Contact CT0
Connection of MELSEC-A Series PLC Connection of MELSEC-F FX Series PLC Connection of Two or More GOT Units Connection of Peripheral Equipment installation and Wiring of Handy GOT installation and Wiring of F940GOT Specifications Outline Introduction Specification of PLC number when using Q multiple PLC system Specify the PLC number when appointing the device.
GOT-F900 SERIES (CONNECTION) Specifications 3 4) FX Series GM positioning unit (GM direct connection) Setting range Device name GT Designer (2) DU/WIN Input (X) *1 X0~X377 X0~X377 Output (Y) Y0~Y67 Y0~Y67 M0~M511 M0~M511 M9000~M9175 M9000~M9175 Bit Internal relay (M) device Special auxiliary relay (SM) GOT internal bit register (GB) GB132~1023 GB132~1023 Data register (D) D0~D3999 D0~D3999 Special data register (SD) D9000~D9313 D9000~D9313 Word File register (R) device Index register
GOT-F900 SERIES (CONNECTION) Specifications 3 5) FREQROL Series inverter (INV direct connection) Setting range GOT internal data register (GD) A0:"~A7:" Pr0:"~Pr993:" Decimal PG0:"~PG89:" 3 SP108:"~SP127:" GD100~1023 4 Specify the station number using either of the following methods. a) Station No. specification (direct) : Specify the station number of the inverter when setting the device. [Available setting range: 0 to 31] "##" indicates a set numeric value. Set "GD100".
GOT-F900 SERIES (CONNECTION) 3.3.
GOT-F900 SERIES (CONNECTION) Specifications 3 3) FLEX-PC N Series manufactured by Fuji Electric Input (X) X0~X7FF X0~X7FF Output (Y) Y0~Y7FF Y0~Y7FF M0~M1FFF M0~M1FFF L0~L1FFF L0~L1FFF Internal relay (M) Bit device Latch relay (L) State (S) S0~S7FF S0~S7FF Special internal relay (M) M800~M81FF M800~M81FF GOT internal bit register (GB) GB132~GB1023 GB132~GB1023 Timer (T) T0~T3FF T0~T3FF Counter (C) C0~C1FF C0~C1FF Data register (D) Word Special data register (D) device Link regist
GOT-F900 SERIES (CONNECTION) Specifications 3 5) MEWNET-FP Series manufactured by Matsushita Electric Works Setting range Device name Input relay (X) *3 GT Designer (2) DU/WIN X0000~X511F X0000~X511F Y0000~Y511F Y0000~Y511F R0000~R910F R0000~R910F L0000~L639F L0000~L639F E0~E2047 E0~E2047 Timer contact (T) *3 T0~T3071 T0~T3071 Counter contact (C) *3 C0~C3071 C0~C3071 GOT internal bit register (GB) *7 GB132~GB1023 GB132~GB1023 Elapsed value of timer/counter (EV) EV0~EV3071 EV0~EV307
GOT-F900 SERIES (CONNECTION) Specifications 3 Introduction 1 a) SLC500 Series i) GT Designer (earlier than Version 5.05F) and DU/WIN (earlier than Version 2.
GOT-F900 SERIES (CONNECTION) Specifications 3 ii) GT Designer 2 (Version 1.02C or later), GT Designer (Version 5.05F or later) and DU/WIN (Version 2.
GOT-F900 SERIES (CONNECTION) Specifications 3 Introduction 1 b) MicroLogix 1000/1200/1500 Series i) GT Designer 2 (Version 1.02C or later), GT Designer (Version 5.05F or later) and DU/WIN (Version 2.
GOT-F900 SERIES (CONNECTION) Specifications 3 7) S7-200/300 Series manufactured by Siemens a) S7-200 Series Setting range Device name GT Designer (2) FX-PCS-DU/WIN Variable Memory (V) V00~V51197 V0.0~V5119.7 Input (I) I00~I77 I0.0~I7.7 Output (Q) Q00~Q77 Q0.0~Q7.7 Bit memory (M) M00~M317 M0.0~M31.7 Bit Special Memory (SM) device Timer (T) *1 SM00~SM1947 SM0.0~SM194.7 T0~T255 T0~T255 Counter (C) *1 C0~C255 C0~C255 Sequence Control Relay (S) S00~S317 S0.0~S31.
GOT-F900 SERIES (CONNECTION) Specifications 3 Input relay (I) Output relay (Q) Bit device Bit memory (M) DU/WIN I0~I5117 I0.0~I511.7 Q0~Q5117 Q0.0~Q511.7 M0~M20477 M0.0~M2047.7 GOT internal bit register (GB) *1 GB132~GB1023 GB132~GB1023 Present value of timer (T) T0~T511 T0~T511 C0~C511 C0~C511 Word Present value of counter (C) device Data register (D) GOT internal data register (GD) Decimal 3 D000100000~D102365534 DB".DBW0~DB".
GOT-F900 SERIES (CONNECTION) 3.4 Specifications 3 Hardware Specifications This section explains the hardware specifications of the GOT-F900 Series. 1) General specifications "o" of the GOT model name indicates 0 or 3.
GOT-F900 SERIES (CONNECTION) Specifications 3 Introduction 1 2 F920GOT-BBD5-K-E F940GOT-SBD-(R)H-E F940GOT-LBD-(R)H-E 5V DC Supplied from PLC 24V DC+10%-15% (separately prepared DC power supply) 220mA/5V DC (180mA/5V DC) 300mA/24V DC (200mA/24V DC) Built-in (irreplaceable) − Built-in (irreplaceable) Operation continues against power failure of 5ms or less. − Operation continues against power failure of 5ms or less. 80mA/24V DC (70mA/24V DC) FX2NC-32BL (life: Approx.
GOT-F900 SERIES (CONNECTION) Specifications 3 1) Switch/lamp/buzzer specifications "o" of the GOT model name indicates 0 or 3. Item F940WGOT F940GOT F930GOT-K Product model name F940WGOT-SWD-E F940GOT-SWD-E F940GOT-LWD-E F930GOT-BBD-K-E Operation switch − − − Function key − − 8 switches Grip switch − − − Emergency stop switch − − − Keylock switch − − − Ten-key keypad − − 0~9, (-), (.
GOT-F900 SERIES (CONNECTION) Specifications 3 4 switches (4 contacts/ common) a contact 10 mV/24V DC Life: 1,000,000 times − 6 switches − − − − − − 1 switch (JSHD4H2 manufactured in 2a contact Sweden) 1A/24V DC 3-positioned OFF/ (resistance load) ON/OFF (individual wiring) − 1 switch (assigned as key in display unit) − − 1 switch (AH165-VR01 manufactured by Fuji Electric) (individual wiring) b contact 1A/24V DC (resistance load) Life: 100,000 times or more − 4 switches (4 contacts/ commo
GOT-F900 SERIES (CONNECTION) Specifications 3 MEMO 3-32
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Connect connection cables securely to the specified connectors while the power is turned OFF. Imperfect connection may cause malfunction or failure. Caution on wiring • Make sure to shut down all phases of the power supply outside the F920GOT-K/F930GOT(-K)/ F940(W)GOT before starting the installation or wiring work. Otherwise, electrical shock and damages of the F930GOT/F940(W)GOT may be caused.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Note • Even if momentary power failure of less than 5 ms occurs in the power supply, the F930GOT/ F930GOT-K/F940(W)GOT continues the operation. If long-time power failure or voltage drop occurs, the F930GOT/F940(W)GOT stops the operation. When the power supply is recovered, the F930GOT/F940(W)GOT restarts the operation. • Use electric wires of 0.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Introduction 1 This section explains installation on the panel face and wiring of the power supply, etc. Wiring and setting procedures This section introduces the procedure to connect the GOT-F900 to connected equipment such as PLC. 2 Reference Outline of Connection You can learn the outline of the connection method. 4.1 Name of each Part You can learn the name of each part of the F930GOT/F940(W)GOT. 4.
GOT-F900 SERIES (CONNECTION) 4.1 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Outline of Connection This section explains the outline of the cables connecting the GOT-F900 to the PLC.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Example: Front panel of F940GOT 1) Display - • Outline P O W E R Alphabets and numbers can be displayed in the size of ×1/2 to ×4 in height and ×1 to ×4 in width.
GOT-F900 SERIES (CONNECTION) 4.2.3 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Function of Ports Connect a PLC unit and peripheral equipment to the following ports of the GOT. F920GOT-K F930GOT F940GOT F940WGOT 4 ) R S 2 3 2 C 1) 2) 2 ) 3 ) F930GOT-K R S 4 2 2 1 ) 1) 1 ) 1 ) 2 ) 2) 1) PLC port (RS-422) 9-pin D-Sub, female - Connect here a PLC through RS-422. - Use this port also to connect two or more GOT units (through RS-422).
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 When connecting a PLC through a computer link unit, use the port 1), 2) or 3). In the F940WGOT, when connecting a personal computer and transferring the screen data, use the port 4). • F940WGOT has two serial ports besides one port for PLC. In connecting two or more GOT units, however, only one of the ports can be used to configure a system. The other port can be used for a printer or a personal computer.
GOT-F900 SERIES (CONNECTION) 4.3 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Outside Dimensions and Panel Face Processing This paragraph explains the specifications of outside dimensions of the GOT-F900, and the panel cut dimensions in processing the panel face. Panel Cut Dimension On the panel face, drill an installation hole of the dimension shown below.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Caution on installation When installing the GOT on the control panel, etc., make sure that the display unit is set at an angle shown in the figure below. If the GOT is installed at any other angle, the GOT may be deteriorated earlier.
GOT-F900 SERIES (CONNECTION) Inner dimension of the panel required for installation When installing the GOT, take into consideration the inner dimension shown below. a) PLC cable b) Packing F920GOT-K 5(0.20) 10 (0.39) COM1 RS232C 70(2.76)(cable) 7 (0.28) 67(2.64) 14.5(0.57) 5(0.20) or less a) The terminal block is provided in the F920GOT-BBD-K. 20(0.79) b) 37.5(1.48) 6.4(0.25) COM0 RS422 20 (0.79) COM1 RS232C a) 30(1.18)(cable) 169(6.65) 104.5(4.11) 20 (0.79) 179(7.05)(screw center) 20(0.
140(5.51) (metal fixture external shape) installation and Wiring of Handy GOT Longitudinal installation installation and Wiring of F940GOT 5 ( 0 .2 0 ) o r le s s a) 130(5.12)(screw center) Connection of Peripheral Equipment 1 5 2 (5 .9 8 ) 1 6 2 (6 .3 8 )(s c re w c e n te r) 1 7 2 ( 6 .
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 F940WGOT 7 0 .6 (2 .7 8 ) 1 2 3 1 4 3 (5 .6 3 ) ( m e ta l fix tu r e e x te r n a l s h a p e ) 1 3 3 (5 .2 4 )(s c re w c e n te r) L a te r a l in s ta lla tio n a ) 2 0 5 (8 .0 7 ) 2 1 5 (8 .4 6 )(s c re w c e n te r) 2 2 5 ( 8 .8 6 ) ( m e ta l fix tu r e e x te r n a l s h a p e ) 5 ( 0 .2 0 ) o r le s s b ) 2 0 5 (8 .0 7 ) 2 1 5 (8 .4 6 )(s c re w c e n te r) 2 2 5 ( 8 .
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Installation procedure The GOT-F900 is so designed as to be embedded in the panel. Install the GOT using the procedure shown below. For the panel cut dimension, refer to the previous page.
GOT-F900 SERIES (CONNECTION) 4.5 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Connector Pin Layout and Signal Name (Excluding the 5 V type F920GOT-K.) The figure below shows the pin layout in the serial interface connector built in the GOT-F900. F920GOT-K (24 V type)/F930GOT/F930GOT-K/F940GOT/F940WGOT RS-422 9-pin D-Sub, female 5 1 9 RS-232C 9-pin D-Sub, male M2.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Outline of Internal Wiring The figure below shows the internal wiring of the GOT-F900.
GOT-F900 SERIES (CONNECTION) 4.7 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Wiring for 24V DC and 5V DC Power Supply and Class D Grounding To the F930GOT/F940(W)GOT, the power is supplied from the PLC or from the external power supply. 1) Current consumption in the GOT-F900 The table below shows the current consumption in each case.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Introduction 1 4) Recommended feature size of terminal F920GOT-K (5V type) No terminal block is provided. 2 F920GOT-K (24V type), F940GOT φ3.2(0.13") Terminal screw Pressure terminal Outline 6.2mm(0.24") or less φ3.2(0.13") 6.2mm(0.24") or less 3 Specifications Terminal When wiring one cable to a terminal φ3.2(0.13") Pressure terminal 4 installation and Wiring of F940GOT 6.3mm(0.25") or more φ3.2(0.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 F 9 4 0 G O T ,F 9 4 3 G O T F 9 4 0 W G O T G r o u n d in g r e s is ta n c e 1 0 0 W o r le s s 2 4 V D C p o w e r s u p p ly G r o u n d in g r e s is ta n c e 1 0 0 W o r le s s 2 4 V D C p o w e r s u p p ly a) Example when the power is supplied from the PLC Connect the power terminal of the F920GOT-K (24V type)/F930GOT/F930GOT-K/F940GOT to the 24V DC service power supply of the PLC or extension unit.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Handling of Function Keys (F1 to F8) (F920GOT-K and F930GOT-K) The ON/OFF status of the function keys is transmitted to the PLC via a communication cable. 2 Outline F930GOT-K Function switch Function switch F1~F4 F5~F8 4 installation and Wiring of F940GOT These keys cannot be used for applications other than a value input and the cursor movement.
GOT-F900 SERIES (CONNECTION) 4.8.1 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Use of function keys This section explains the use of the function keys and the indicator LEDs (only in the F930GOT-K). 1) Wiring of function keys No wiring of the function keys is required because the keys and the connected equipment (PLC) communicate via a communication cable.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 This section explains how to prepare the function key name sheet. 1) Preparing the name sheet a) Make the mount sheet in reference to the following dimensions and prepare an OHP sheet (transparent and colorless sheet). b) Write down the names of the switches used on the mount sheet. Function key 3 6(0.24") C2(0.08") Insertion direction. 4 installation and Wiring of F940GOT C2(0.08") 3(0.
GOT-F900 SERIES (CONNECTION) 4.8.3 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Cautions on use With regard to the function keys (Operation Panel), the priority is given to the base screen and overlap windows. If there are two or more types of setting, only the setting on a screen having higher priority is valid in the unit of function key No.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Label pattern (F930GOT-K) Copy this pattern to the OHP sheet offered as an accessory.
GOT-F900 SERIES (CONNECTION) 4.9 Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Setting of Connected Equipment for GOT The setting in the screen creation software is required to turn on and off the function keys and LED display using the connected equipment. This section describes the setting method. 1) GOT-F900 Series No setting is enabled on the GOT. Set items in either one of the screen creation software mentioned below.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Operation Display (screen name) Unit of screen (individual) Select "Project"-"Base Screen" from the project work space, leftclick the screen No. to be set, then select "Operation Panel" on the submenu.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Caution on setting of "Lamp (External)" 1. The contents of "Lamp (External)" you have set are not displayed on the screen. 2. The setting of "Lamp (External)" is valid only in the F920GOT-K, F930GOT-K and Handy GOT. Never set it in any other series. 3. Set only one lamp for all screens of the created screen data. 4.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Introduction 1 Screen display of GT Designer2 "*" indicates that a switch operation is set. 2 Operation Panel Outline * Available Operation Panel 3 Specifications Click a box indicating a function key, then set its functions (example: F1). Currently set switch functions are displayed.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 3) GT Designer Operation [Setting] a)It is supposed that the GT Designer has started up and the screen data to be set is read. b)Open a user screen to be set. Any screen is available as far as it has been already created. Select and display the base screen (B-1) in this example. [LED setting] c)Select "Draw"-"Animation Display"-"Lamp" on the menu. Display (screen name) The "Lamp" dialog box appears.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 1. The check box of "Available Operation Panel" is valid only in the F920GOT-K, F930GOT-K and Handy GOT. Do not set it in any other series. 2. The operations of the keys (F1 and others) can be set using devices (+00 ~ of X000) in "Edit Operation Panel" in the screen creation software.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 4) DU/WIN Operation [Setting] Display (screen name) a)It is supposed that the DU/WIN has started and the screen data to be set has been read. b)Select "Common Screen" on the "Screen List" window (highlighted when clicked). If the window is closed, select "View/Project"-"Screen List" on the menu. [LED setting] The LEDs for the function switches are set on "Common Screen". c)Click the [Objects] button.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 Operation [Switch setting] Display (screen name) g)Click the [Keys] button. The "Keys Scr. Common" window appears. Introduction 1 Outline 2 Specifications 3 h)Allocate a switch operation to an External Key (n) in the "Keys" list pressing the [Add] button. Refer to Setting of function key below. The switch operations can be set to devices (external keys 0 to 7) corresponding to F1 to F8.
GOT-F900 SERIES (CONNECTION) Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4 MEMO 4-32