Back Light FD Series Inverter Packaged Air Conditioners MHIAA is proudly sponsoring Monika’s Doggie Rescue
FD Series. Inverter Packaged Air Conditioners. change setting by button taps only Run / Stop High power operation Energy-saving operation Maximum capacity operation (Max 15 minutes) • Increased compressor speed • Increased air flow • Changes set temperature at 28ºC in cooling mode and 22ºC in heating mode, 25ºC in auto mode.
Basic operation All settings are changed by tapping the touch screen panel PRODUCTS Advanced touch screen panel with full dot Liquid Crystal Display Operation mode setting screen Temperature setting screen The operation mode can be selected by simply tapping this button. You can select the desired temperature by tapping the ▲▼ button.
FD Series. Hyperinverter. Our advanced technology has allowed us to achieve high efficiency, powerful heating and long distance refrigerant piping specifications. This feature permits installation of the units when a heating operation under temperature conditions down to -20˚C is required. Design flexibility has been improved by an extension of the refrigerant piping length to 100m (12.5 & 14.0kW). Blue Fin Micro 5.0 & 6.0kW Blue Fin 7.1kW 10.0kW 12.5 & 14.
Micro Inverter 8.8 0 -15C 2C 50C 40C Hyper Inverter 30C 20C 7C 10C Micro Inverter 0C 4minutes 8minutes Micro Inverter Compact design of outdoor units FDC100VN 10.0kW Reduction in height by 22.3% * Vector control: To convert the current wave to a smooth sinusoidal waveform. Size reduction and high efficiency performance of the DC twin rotary compressor The DC twin rotary compressor can operate New model DC rotary compressor at speeds as high as 120 rps to achieve the required capacity.
FDT-FDTC. Ceiling Cassette - 4way - Indoor units. Individual flap control system Individual flap control is available even after installation. This means that the installation area has become wider than before. The outlet design has been perfected to allow sufficient air flow that can reach a long distance from the indoor unit. Previous Previous Upper position Flap control system The design of the heat exchanger has changed from 2 parts to a single piece.
FDUA Indoor Unit. Duct Connected - High Static Pressure. PRODUCTS External static pressure (E.S.P.) control Selecting the external static pressure setting the optimum air flow volume can be achieved. The indoor unit will recognize the external static pressure setting and keep rated air volume. New FDUA Duct Duct Longer Duct Ceiling Keep the same air flow volume Setting No. 1 E.S.P.
FDUA Indoor Unit. Duct Connected - High Static Pressure. Wired Remote Control RC-EX1A Wireless Remote Control RC-E5 RCH-E3 RCN-KIT3-E Wired Remote Control RC-EX1A W RC-E5 RCH-E3 FDUA71~160VF Dimension H 398 H 280 (1) Indoor units Model FDUA71VF 65 39 Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.
FDUA FDUA100VNVF FDUA100VNXVF FDUA125VNXVF FDUA140VNXVF FDUA71VF FDUA100VF FDUA100VF FDUA125VF FDUA140VF FDUA160VF Outdoor FDC71VNX FDC100VN FDC100VNX FDC125VNX FDC140VNX FDCA160VS 7.1 (3.2-8.0) 10 (4.0-11.2) 10 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-14.5) 16.0 (7.0-20.0) 8.0 (3.6-9.0) 11.2 (4.0-12.5) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) 18.0 (7.6-22.4) Heating H2 5.9 10.0 13.5 14.0 15.0 15.0 Cooling T1 2.22 3.05 2.85 3.83 4.44 5.02 2.22 2.87 2.74 3.
FDUM Indoor Unit. 10 Duct Connected - Medium Static Pressure. Wired Remote Control RC-EX1A Wireless Remote Control RC-E5 RCH-E3 RCN-KIT3-E Wired Remote Control RC-EX1A FDUM50 ~ 140VF RC-E5 Thin design Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location. The height of all FDUM models is only 280mm.
FDUM FDUM50ZJXVF Power supply FDUM71VNXVF FDUM100VNVF FDUM125VNXVF FDUM140VNXVF FDUM50VF FDUM60VF FDUM71VF FDUM100VF FDUM125VF FDUM140VF SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VNX FDC140VNX 5.0 (2.2-5.6) 5.6 (2.8-6.3) 7.1 (3.2-8.0) 10.0 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-14.5) 5.4 (0.6-6.3) 6.7 (0.6-7.1) 8.0 (3.6-9.0) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) Outdoor Unit 1 Phase 230V 50Hz Cooling T1 Capacity Heating H1 Input kW Heating H2 4.3 4.9 7.
FDT - Indoor Unit. 12 Ceiling Cassette-4way.
Infrared control option Detachable covers at each corner allows for easy alignment and balance. The panel does not need to be removed. Installation time is reduced. For wireless control simply insert the infrared receiver kit on the corner. PRODUCTS Installation wireless remote control wireless remote control RCN-T-36W-E RCN-T-36W-E wireless remote remote control control wireless RCN-T-36W-E RCN-T-36W-E Easy checking of drain pan 700mm Drain Pump To check the drain pan simply remove the corner lid.
FDTC - Indoor Unit.
Taking OA (Outside air intake) into inside Ceiling OA surface OA surface Ceiling OA surface Spacer Panel OA Panel OA Panel Joint Duct Ceiling OAJoint Duct “CLEARER”Air Flow 35dB (dB) 35 36 34 35 35dB 33 34 32 33 Joint Duct 34 34 33 33 32 (dB) 3632 29 30 28 29 30 3430 3329 32 28 5dB 3127 Down 5dB 30 26 Down 29 30dB29 30dB28 26 25 5dB Previous New Previous New New (Cooling/Heating) (Cooling/Heating) (Cooling) 27 32dB 30dB Down 28 3dB Down Down Down 27 25 Previous 26 (C
FDEN - Indoor Unit. Ceiling Suspended. FDEN100/125VF FDEN 100/125VF Remote control (Option) Remote control (Option) Remote control (Option) Wireless Wireless Wireless Wired Wired Wired FDTC50VF RCH-E3 RC-EX1ARC-EX1A RC-E5 RC-E5 RC-EX1A RC-E5 FDTC50VF Remote control (Option) RCN-TC-24W-ER RCH-E3 RCN-E1R RCH-E3 RCN-TC-24W-ER Wireless Wired Outline drawing (Unit:mm) 290(Suspension bolts pitch) 24 5 135 b 40 e d 173 RC-EX1A Holes for suspension bolts (M8 to M10x4pcs.
Improved installation workability Compact and modern design Increased freedom of a piping layout Height Height 250mm 250mm Right Right PRODUCTS Up Up Rear The refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below. All models fit compactly on ceiling. (Height-210mm or 250mm).
Hyperinverter. Outdoor Unit 5.0-14.0kW. Micro SRC50/60ZJX-S FDC100VN FDC71VNX FDC125/140VNX Blue Fin 7.1-14.0kW Base heater kit (option) Due to application of blue coated fins (KS101) for the heat exchanger of the new outdoor unit, corrosion resistance has been improved compared to previous models. This kit is recommended for use in areas where the temperature drops below 0˚C. Blue Fin Blue Fin CW-H-E applied for FDC100VN FDC125~140VNX Installation workability.
High efficiency. Increase of heat transfer efficiency Pressure caused by air flow in the indoor unit is reduced by making the air outlet larger. The reduction of pressure reduces the load on the fan motor so efficiency increases. Heat transfer efficiency has improved by using high efficiency piping and by the redesign of the heat exchanger from 2 to 1 piece. PRODUCTS Reduction of air flow pressure loss Convenience.
SUPERLINK- Control System. KX6 series SC-SL1N-E RAC series (SRK/SRF-ZJX-S) SC-BIKN-E SC-ADNA-E SC-SL2NA-E SC-ADNA-E SC-ADNA-E Central Control SC-SL1N-E SC-SL2NA-E SC-SL3N-AE/BE Start/stop control of up to 16 indoor units is possible either individually or collectively. With simple operations, you can effect centralised control. Centralised control of up to 64 indoor units. Allows connection with a weekly timer without using any interface.
SUPERLINK E BOARD (SC-ADNA-E) (1) Functions (a) Transmits the settings from the network option to the indoor units. (b) Returns the priority indoor unit data in response to a data request from the network option. (c) Inspects the error status of connected indoor units and transmits the inspection codes to the network option. (d) A maximum of 16 units can be controlled (if in the same operation mode).
Control System. Individual Control. Remote Control line up indoor unit wired remote control RC-E5 all models RCH-E3 wireless indoor unit FDT FDTC FDUM, FDU FDEN remote control RCN-T-36W-E RCN-TC-24W-ER RCN-KIT3-E RCN-E-E Wired remote control with weekly timer (option) RC-E5 Run hour metres to facilitate maintenance checking RC-E5 stores operation data when an anomaly occurs and indicates the error on the LCD.
KX-KXR. Industry leading energy efficiency and reliability from our advanced technology. PRODUCTS Mitsubishi Heavy Industries offers one of the largest ranges of VRF multi inverter products in the industry. The compact M series (11.2 to 15.5kW) is a single fan, single phase outdoor that is providing air conditioning solutions all over Australia and New Zealand. The larger side blow (22.4 to 33.
Before starting use Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.