R410A High Performance Air Conditioning FD series Inverter Packaged Air-Conditioners 50/60Hz 09P02E-A-0
Individual flap control system According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, installation area became wider than before.
Ceiling Cassette -4wayIndoor units FDT,FDTC For person who is far from the indoor unit For both persons who are feeling hot or cold Can cool both the kitchen and the guests 3
New Inverter Series All models employ R410A, with RoHS* directive R410A RoHS *RoHS : Restriction of Hazardous Substances Industry Leading COP Thanks to achievement of the highest COP level in the industry, the energy consumption has been cut by 30~49% compared with our former models (constant speed models). A Energy labeling “Class A” CLASS MHI models have cleared the class A standard, the highest energy saving level, with their high COP (coefficient of performance). A B C D E F G Achieved COP 5.
Individual flap control system (FDT, FDTC) According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, installation area became wider than before. Flap control system Selection of louver position is possible. Louvers can be set at different angles.
Industry leading energy efficiency and Height Height 185mm 390mm Height 455mm Height 95mm Width Width 380mm 380mm Depth Depth 350mm FDC71VN (3.0HP) FDC100VN/VS (4.0HP) FDC125VN/VS (5.0HP) FDC140VN/VS (6.0HP) FDC200VS (8.0HP) Reduction in weight (kg) Easy installation Fits into elevators 350mm FDC250VS (10.0HP) Reduction in volume (%) Former model New model Reduction 3.0HP 4.0HP 5.0HP 6.0HP 8.0HP 10.
high reliability from our high technology POINT 1 1 POINT 2 DC fan motor uses less energy Optimization of heat exchanger path. More efficient heating and cooling 2 3 POINT 3 POINT 4 4 Super heat control with low pressure sensor, works better in tough conditions High efficiency refrigeration circuit 5 POINT 970 mm mm 370 FDC200VS 5 Newly developed High efficiency DC scroll compressor (8.
SINGLE [OUTDOOR UNIT : INDOOR UNIT = 1 : 1] Capacity Type 4way FDT HP kW Btu / h kcal / h 1.5 4.0 13,700 3,440 2.0 5.0 17,100 4,300 2.5 6.
Range (Rated Cooling Capacity) 3.0 7.1 23,900 6,020 4.0 10.0 34,100 8,600 5.0 12.5 42,700 10,750 6.0 14.
INDOOR UNIT CEILING CASSETTE -4way- FDT A R410A CLASS FDT 40/50/60/71/ 100/125/140V Wired remote control Wireless remote control RC-E3 RCH-E3 RCN-T-36W-E (Option) (Option) (Option) Outline drawing (Unit:mm) Model FDT40,50,60,71V Model 100,125,140V Point 1 Arrangement of installation balance of indoor unit Checking from access ports with detachable covers at each corner, arrangement of installation balance of indoor unit can be available without removing a panel.
SPECIFICATIONS Point 2 Easy checking of drain pan Power source Indoor unit Drain can be discharged upwards by 700mm from the ceiling surface. It allows a piping layout with a high degree of freedom Depending on the installation location and 260mm Flexible hose flexible hose as a standard equipment less than supports easy 700mm workability.
INDOOR UNIT A CEILING CASSETTE -4way Compact (600 X 600mm)- FDTC R410A CLASS Fits into standard 600 x 600 ceiling NEW FDTC 40/50/60VB Wired remote control Point Wireless remote control RC-E3 RCH-E3 RCN-TC-24W-ER (Option) (Option) (Option) Point 1 Quiet operation 2 “CLEARER”Air Flow (Sound level in the Lo mode) 3dB Down (dB) 36 35dB 35 New shape & angled louver redirects the air current away from the ceiling, to reduce ceiling stains 34 33 32dB 32 31 30dB 30 29 Point 5dB Down
Outline drawing (Unit:mm) SPECIFICATIONS The values are for simultaneous Multi operation. Set model name Indoor name Outdoor name FDTC40ZIXVB FDTC40VB SRC40ZIX-S 1Phase 220-240V 50Hz, 1Phase 220V 60Hz Power source Type Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Cooling/Heating Input Cooling/Heating COP Cooling/Heating Energy label Inrush current (Max.
INDOOR UNIT A DUCT CONNECTED -High Static pressure- FDU Wired remote control CLASS R410A Fan control kit (100~200Pa) Wireless remote control FDU71/100/125/140V U-FCRA RC-E3 RCH-E3 RCN-KIT3-E (Option) (Option) (Option) [For 200/250V] (option) FDU200/250V Outline drawing (Unit:mm) FDU71V FDU100,125,140V FDU200,250V Point 1 Enhanced installation workability Quiet, Lightweight and Compact With the FDU71, the noise level is only 37dB (low), weight is only 40kg and height is only 297mm.
SPECIFICATIONS The values are for simultaneous Multi operation. FDU71VNV FDU71V FDC71VN Set model name Indoor name Outdoor name * FDU100VNV FDU100V FDC100VN * FDU125VNV FDU125V FDC125VN * Range of usage Outdoor unit Indoor unit Type Nominal cooling capacity 7.1 ISO-T1(JIS) kW (3.2~8.0) (Min~Max) 8.0 Nominal heating capacity ISO-T1(JIS) kW (3.6~9.0) (Min~Max) Cooling/Heating Input kW 2.08/2.21 Cooling/Heating COP 3.41/3.62 Cooling/Heating Energy label A/A Inrush current (Max.
INDOOR UNIT DUCT CONNECTED -Middle Static pressure- FDUM UM-FL1E : for 50 UM-FL2E : for 60, 71 UM-FL3E : for 100,125,140 1 Various Adaptability 16 RC-E3 RCH-E3 (Option) (Option) Wireless remote control RCN-KIT3-E (Option) 2 600mm Drain Pump (50/60Hz) model Standard Max 50V 50/40 85/90 60/71V 50/40 85/100 100V 60/60 90/100 125/140V 60/55 85/100 Drain can be discharged upwards by 600mm from the ceiling surface.
SPECIFICATIONS Outline drawing(Unit:mm) The values are for simultaneous Multi operation. Set model name Indoor name Outdoor name Power source Type Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) Cooling/Heating Input kW Cooling/Heating COP Cooling/Heating Energy label Inrush current (Max.
INDOOR UNIT CEILING SUSPENDED A FDEN R410A CLASS FDEN 40/50/60/71/100/125/140V Wired remote control Wireless remote control RC-E3 RCH-E3 RCN-E1R (Option) (Option) (Option) Outline drawing (Unit:mm) 290(Suspension bolts pitch) 24 b 40 52 68 Liquid piping 100 or more Gas piping e d 173 5 135 Space for installation and service Holes for suspension bolts (M8 to M10X 4pcs.
SPECIFICATIONS Point 3 New design --Drastic-reduction of noise level Reviewing sirocco fan (diameter and wide) enables drastic reduction of noise level. Sound pressure level:dB(A) dB(A) 50 45 40 New model Former model 39 38 38 37 37 Lo-mode 44 43 43 39 38 43 39 Set model name Indoor name Outdoor name FDEN40ZIXV FDEN40V SRC40ZIX-S 25 20 1.5 2.0 2.5 3.0 4.0 5.0 6.
MULTI SYSTEM Up to Four indoor units can be connected to a single outdoor unit and simultaneously operated with a single remote control. Twin / Triple / Double Twin Multi System By referring to the following table for applicable indoor units, select the same models and capacities.
Ideal for the installation in large area and L-shaped rooms, the V Multi System has an extensive degree of flexibility in the selection of indoor units. Specifically, the selection of indoor units with different capacities in different types can be made. V Multi System Different models and capacities can be selected.
MULTI [ INDOOR UNIT ] WALL MOUNTED SRK A CLASS R410A Only used with outdoor units of TWIN, TRIPLE MULTI System. NEW SRK 50/60ZIX-S Wired remote control RC-E3 RCH-E3 (Option) (Option) Outline drawing (Unit:mm) 60 21 61.5 60 46.5 Piping hole right 61.5 (right, left)61.5 26 9 3.1 309 881.9 3 46.5 220 890 Terminal block 122.1 Point 1 Jet Air Scroll We used the same aerodynamic analysis technology as used in developing jet engines.
Point Point 2 Long Reach Air Flow 3 Flap control system Selection of louver position is possible. Louvers can be set at different angles. Powerful airflow is realized by Jet technology. Good for large living rooms and shops. Increase your comfort. Upper position SRK50/60ZIX-S (in cooling operation) 15m Movable range Lower position Max four indoor units are connectable. SC-BIKN-E SC-BIKN-E SC-BIKN-E RC-E3 SPECIFICATIONS The values are for simultaneous Multi operation.
MULTI [ INDOOR UNIT ] CEILING CASSETTE -4way- FDT 40/50/60/ 71/100/125V FDT A Indoor unit Range of Outdoor unit usage RCH-E3 RCN-T-36W-E (Option) (Option) (Option) FDT100VNPV FDT125VNPV FDT140VNPV FDT140VNTV FDT100VSPV FDT125VSPV FDT140VSPV Twin Triple Twin FDT50V FDT50V FDT60V FDT71V FDT50V FDT60V FDT71V FDT40V FDC140VN FDC100VS FDC125VS FDC140VS FDC100VN FDC125VN FDC140VN FDC71VN 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz Inverter 14.0 10.0 14.0 12.5 10.0 12.
CEILING CASSETTE -4way Compact (600 X 600mm)- FDTC A CLASS SPECIFICATIONS The values are for simultaneous Multi operation. FDTC71VNPVB Set model name Indoor name Outdoor name Power source Type Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Input Cooling/Heating COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max.
MULTI [ INDOOR UNIT ] DUCT CONNECTED -Low/Middle Static pressureFDUM 50/60/71/100/125V FDUM A CLASS SPECIFICATIONS RC-E3 RCH-E3 RCN-KIT3-E (Option) (Option) (Option) FDUM100VNPV Range of Outdoor unit Indoor unit usage Indoor name Outdoor name Power source Type Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) Input Cooling/Heating kW COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max.
CEILING SUSPENDED Wired remote control FDEN FDEN 40/50/60/71/100/125V A CLASS SPECIFICATIONS Range of Outdoor unit Indoor unit usage Indoor name Outdoor name Power source Type Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) Input Cooling/Heating kW COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max.
OUTDOOR UNIT (1.5-10.0HP) SRC40ZIX-S SRC50ZIX-S* SRC60ZIX-S* (1.5HP~2.5HP) FDC71VN (3.0HP) is common for both *SRC50/60ZIX-S of outdoor units of SRK50/60ZIX-S (Residential Air-conditioners) and 1.5, 2, 2.5HP of Inverter Packaged Air-Conditioners. Common components make for easy inventory control and the installation procedure will be the same. FDC100VN, FDC125VN FDC140VN, FDC100VS FDC125VS, FDC140VS (4.0HP~6.0HP) FDC200VS (8.0HP) FDC250VS (10.
Control Systems [Individual control] Remote Control line up indoor unit wired all models remote control RC-E3 RCH-E3 wireless indoor unit FDT FDTC FDU, FDUM FDEN remote control RCN-T-36W-E RCN-TC-24W-ER RCN-KIT3-E RCN-E1R Wired remote control with weekly timer (option) RC-E3 Run hour meters to facilitate maintenance checking RC-E3 stores operation data when an anomaly occurs and indicates the error on the LCD.
Control System SUPERLINK- KX6 series SC-SL1N-E RAC series (SRK/SRF-ZIX-S) SC-BIKN-E SC-ADN-E SC-SL2N-E SC-ADN-E SC-ADN-E Central Control SC-SL1N-E Start/stop control of up to 16 indoor units is possible either individually or collectively. With simple operations, you can effect centralized control. PC windows central control SC-SL2N-E SC-SL3N-AE/BE Centralized control of up to 64 indoor units. It can allow connection with a weekly timer without using any interface.
SUPERLINK E BOARD (SC-ADN-E) This board is used when conducting control of the single package (wired remote control unit) 1-type series using a network option (SC-SL1N-E, SC-SL2N-E, etc). (1) Functions (a) Transmits the settings from the network option to the indoor units. (b) Returns the priority indoor unit data in response to a data request from the network option. (c) Inspects the error status of connected indoor units and transmits the inspection codes to the network option.
OUTDOOR UNIT DIMENSIONS SRC40ZIX-S, 50ZIX-S, 60ZIX-S (unit:mm) FDC71VN (unit:mm) 32
FDC100VN, 125VN, 140VN 100VS, 125VS, 140VS (unit:mm) FDC200VS (unit:mm) 33
OUTDOOR UNIT DIMENSIONS FDC250VS (unit:mm) 34
MEMO 35
Before starting use Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.