High Performance Air Conditioning FD series Inverter Pac k a g e d A i r C o n d i t i o n e r s
Individual flap control system According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred. Individual flap control is available even after installation.
Ceiling Cassette -4wayIndoor units FDT For the person who is far away from the indoor unit For when one person feels hot and the other cold Can cool both the kitchen and the guests
High Efficiency QUICK CONTROL & HIGH EFFICIENCY DC PAM inverter DC compressor motor Magnet Motor Motor Efficiency(%) An inverter system has a number of advantages over a constant speed system. It’s variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides higher performance.
High Efficiency Current New 3-core 2-core New remote control RC-E3 New remote control for all indoor units Non-polar 2 core wiring now used. Installation is easier. Individual flap control system Four directions of air flow can be arranged by individual flap control. Our new outlet design enables the right amount of air to reach all corners of the room. Pressure loss caused by airflow in the indoor unit has been reduced.
High Efficiency High performance and energy efficiency are achieved at the same time by an increase in the heat exchanger capacity and by using DC fan motors. Non Inverter ■ Cool Only Wall-split System - Size reduction and high efficiency performance of the DC twin rotary compressor The DC twin rotary compressor can operate at speeds as high as 120 rps to achieve the required capacity. Vector control and has provided the optimum compressor control.
Product line up ■ Cool Only Wall-split System Model 2.0 2.5 SRK-ZIX series ModelNEW FDT Caseette SRF-ZIX series Floor Standing type 20ZIX-S R410A Capacity Range (kW : Rated cooling capacity) 3.5 4.0 5.0 5.6 6.0 6.3 7.1 Capacity Range (kW : Rated cooling capacity) 4.0 5.0 6.0 7.1 25ZIX-S 35ZIX-S 50ZIX-S 25ZIX-S 35ZIX-S 50ZIX-S 10.0 12.5 14.0 60ZIX-S NEW HEAT PUMP DC INVERTER 2.
Indoor Unit FDT Ceiling Cassette - 4way FDT 60/71/100/125/140V Wireless remote control Wired remote control RCN-T-36W-E (Option) RC-E3 (Option) RCH-E3 (Option) Outline drawing (Unit:mm) Model FDT 60,71V Model FDT 100,125,140V Installation Infrared control Detachable covers at each corner allows for easy alignment and balance. The panel does not need to be removed. Installation time is reduced. For wireless control simply insert the infra-red receiver kit on the corner.
■Easy Cool OnlyofWall-split System - Non checking 700mm DrainInverter Pump drain pan The drain pump can discharge up to 700mm from the ceiling surface. To check the drain pan simply remove the corner lid. Model operational data Rated Capacity Cool/Heat Power Input Cool/Heat FDT71VNV FDT100VNV FDT125VNV FDT140VNV kW 5.6/6.7 7.1/8.0 10.0/11.2 12.5/14.0 14.0/16.0 kW/h 1.57/1.85 1.90/2.07 2.76/2.74 4.05/3.77 4.98/4.57 3.57/3.62 3.74/3.86 3.62/4.09 3.09/3.71 2.81/3.
Indoor Unit ■ Cassette - 4way Compact (600x600mm) ■ Cool Only Wall-split System - Non Inverter FDTC FDTC 40/50V Wireless remote control RCN-TC-24W-ER (Option) Outline drawing (Unit:mm) 10 High Performance Air C o n d i t i o n i n g Wired remote control RC-E3 (Option)
High Efficiency Clearer airflow Infrared control ■ Cool Only Wall-split System - Non Inverter For wireless control simply insert the infra-red receiver kit on the corner. The new shape and angle of the louver directs the air current away from the ceiling reducing ceiling stains. Compact design 248 Height dimension is only 248mm Panel size is only 700x700mm. The indoor unit is 570x570mm ideal for suspended ceilings.
Indoor Unit ■ Ducted - Medium Static Pressure FDU RCH-E3 (Option) Wired remote control FDU71/100/125/140V RC-E3 (Option) RCN-KIT3-E Return air option Outline drawing (Unit:mm) FDU71V FDU100,125,140V Quiet, Lightweight and Compact The FDU71 noise level is only 37dB on low fan. Weight is only 40kg and height 297mm. In addition a 600mm drain pump is mounted in all models. The indoor unit is concealed in the ceiling making it the ideal choice for homes and commercial premises.
High Efficiency Model indoor operational data Rated Capacity Cool/Heat Power Input Cool/Heat FDU71VNV FDU100VNV FDU125VNV FDU140VNV kW 7.1/8.0 10.0/11.2 12.5/14.0 14.0/16.0 kW/h 2.08/2.21 2.88/2.99 4.04/3.79 4.95/4.43 3.41/3.62 3.47/3.75 3.09/3.69 2.83/3.
Indoor Unit ■ Ducted - Medium Static Pressure R410A FDUM Wired remote control RCN-KIT3-E 1 Adaptable (Option) 2 600mm Drain Pump Selectable static pressure and Flexible duct design with selectable air suction (direct suction /duct suction) can meet a wide range of installations. Static pressure Pa model Standard Max 50/60V 50 85 Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.
High Efficiency Indoor Unit Model indoor operational data Rated Capacity Cool/Heat Power Input Cool/Heat FDUM50VHX-S FDUM60VHX-S kW 5.0/5.4 5.6/6.7 kW/h 1.52/1.41 1.86/1.96 3.29/3.83 3.01/3.
Indoor Unit ■ Ceiling Suspended FDEN Wired remote control Wireless remote control RC-E3 RCN-E1R (Option) (Option) Outline drawing (Unit:mm) a (Suspension bolts pitch) 24 290(Suspension bolts pitch) 5 24 135 Holes for suspension bolts (M8 to M10X 4pcs.
High Efficiency Installation Compact design Up Height 210mm Right Rear Refrigeration piping can be set in three directions and the drain pipe arranged in two directions making installation easier. The unit is serviceable from the bottom. Model operational data Rated Capacity Cool/Heat Power Input Cool/Heat FDENVA251HEN1R FDEN100VNV kW 5.60/6.70 10.0/11.2 kW/h 1.74/1.87 2.85/2.97 3.22/3.58 3.51/3.
Outdoor Unit OUTDOOR UNIT (4.0-14.0kW) SRC40ZHX-S SRC50ZHX-S SRC60ZHX-S FDC71VN FDC100VN FDC125VN FDC140VN Installation workability Enhanced installation workability thanks to the extended pipe length – one of the longest levels in the industry and pre-charged refrigerant. 1 Piping length – 50m Point Piping length can be extended up to 50m for single type, which allows wider design flexibility. Height difference (Outdoor>indoor) 4.0 ~ 6.0kW 7.1~14.0kW 20m 30m Piping length 4.0 ~ 6.0kW : 30m 7.
Control System (Individual High Efficiency Control) Control Systems [Individual control] Remote Control line up ■ Cool Only Wall-split System indoor unit wired all models remote control RC-E3 RCH-E3 wireless control Non Inverterremote RCN-T-36W-E indoor unit FDT FDTC FDUM, FDU FDEN RCN-TC-24W-ER RCN-KIT3-E RCN-E1R Wired remote control with weekly timer (option) RC-E3 Run hour meters to facilitate maintenance checking RC-E3 stores operation data when an anomaly occurs and indicates the error on th
Control System ■ WIRED Control (RC-E3) The RC-E3 control allows access to service and maintenance data and easy to use comfort functions. Improved Functionality Weekly timer function as standard RC-E3 provides a 7day 24hr timer which allows programming of weekly operating schedules to be registered. The user can specify up to four times a day to start / stop the air conditioner. Temperature setting is also possible with the timer.
Control System ■ Control System SUPERLINK-II Control System SUPERLINKKX6 series SC-SL1N-E RAC series (SRK50/60ZHX-S) SC-BIKN-E SC-ADN-E SC-SL2N-E SC-ADN-E SC-ADN-E Central Control SC-SL1N-E SC-SL2N-E SC-SL3N-AE/BE Start/stop control of up to 16 indoor units is possible either individually or collectively. With simple operations, you can effect centralized control. Centralized control of up to 64 indoor units. It can allow connection with a weekly timer without using any interface.
Control System SUPERLINK E BOARD (SC-ADN-E) ■ SUPERLINK E BOARD (SC-ADN-E) This board is used when conducting control of the single package (wired remote control unit) 1-type series using a network option (SC-SL1N-E, SC-SL2N-E, etc). (1) Functions (a) Transmits the settings from the network option to the indoor units. (b) Returns the priority indoor unit data in response to a data request from the network option.
Other Products ■ Other Products SRK SRF series - Inverter Wall-split & Floor Standing System The DC inverter wall-split & floor standing system is designed to condition residential spaces such as bedrooms and living areas. Three different styles of wall-split indoor units from 2.0kW to 8.0kW. SRKZG-S SRKZIX-S High efficiency SRFZIX-S NEW 2.5, 3.5 & 5.
Outdoor Unit Dimensions OUTDOOR UNIT DIMENSIONS SRC40ZIX-S, 50ZIX-S, 60ZIX-S (unit:mm) Terminal block 148.4 33.5 Intake 640 L2 B Check joint outlet 93 A 351.6 Mark A B D E 83.5 290 312.5 43.5 L1 L2 L3 L4 24.3 12 327.3 327.3 17.9 510 201 E 800 1 2 3 Open 280 280 100 75 Open 100 80 80 250 Open 250 Item Refrigerant gas side pipe connection tap Refrigerant liquid side pipe connection tap Drain discharge port Anchor bolt hole ø12.7(flare) ø6.35(flare) ø20.
Outdoor Unit Dimensions ■ Outdoor Unit - 7.1 to 14.0kW FDC71VN (unit:mm) L4 150 Intake D 47.5 D outlet L1 19 15 Intake L3 L2 532 223 60 Service space 580 61 Dimensions 2-ø15 150 580 880 25.8 29.8 150 19 61 L1 L2 L3 L4 87.9 E 1 2 3 Open 300 100 250 Open 250 150 250 500 Open 100 250 222 150 55 40 20 Terminal block Mark A B C D E F B 25.5 750 165.
Before starting use Heating performance Refrigerant leakage Indication of sound values Use in snowy areas The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.