Specifications

30
3. Replacement of FX2NC series
3.3.2 Cautions about hardware
z Comparison of FX2N series and FX3U series and cautions for replacement
This is a list of hardware cautions. When performing replacement, please refer to the manual of each
model and conrm details there.
Hardware differences of FX
2NC series and FX3UC series, and cautions
No. Item
Difference
Caution
FX
2NC series FX3UC series
1
Battery and
mounting position
FX2NC-32BL
lithium thionyl
chloride primary
battery
FX3U-32BL
lithium manganese
dioxide primary
battery
Type name (model) is different.
Mounting position is different.
2 Voltage of battery
Nominal voltage
3.6V
Nominal voltage
3.0V
Be careful when using special
device D8005 (battery voltage).
3
Product width
dimension
-
Width of main unit
is shorter by 0.3 to
1mm depending on
the model.
See Fig. 1 on next page.
4
Input hardware lter
(when digital lter
is zero)
High-speed
counter
Input interrupt
function
Pulse catch
function
X0, X1: 20μs
X2 to X7: 50μs
X10 to X17: 200μs*
*16-I/O point main
unit: 10ms
X0 to X5: 5μs
X6, X7: 50μs
X10 to X17: 200μs*
*16-I/O point main
unit: 10ms
Noise, not detected in FX2NC, may
affect input of FX3UC.
If necessary, implement a noise
countermeasure external to the
main unit.
5
Terminal end
resistance of
485ADP
Packaged together
with ADP; to
be selected and
mounted.
Built into ADP;
selectable using a
switch.
In FX3UC, the resistance value can
be selected using a built-in switch.
6
Wire size of
485ADP
AWG26 to 16 AWG22 to 20
Wire size is different. A large wire
size may not be usable in FX3UC.
(See cable size in Table 1. below).
Table 1. Cable size European terminal type connectors
For connection with RS-485 communication equipment, use a twisted pair cable with shielding.
Conforming wire size and tightening torque are as follows.
Wire size
of one-wire
connection
Wire size
of two-wire
connection
Wire ferrule
with insulation
sleeve
(wire size)
Tightening
torque
Insulation
sheath
stripping
length
*
FX2NC-485ADP
AWG26 to
AWG16
AWG26 to
AWG20
Not usable 0.4 to 0.5N·m 8mm
FX
3U-485ADP(-MB)
AWG22 to
AWG20
AWG22
Usable
(AWG22 to
AWG20)
0.22
to
0.25N
·
m
9mm
* Insulation sheath stripping length shows the dimension when connecting the wire to the terminal
directly.
For details, please refer to the FX Series Users Manual (Data communication edition) JY997D16907.