Specifications

EZ Motion E series
SUPER
25
Model Applicable servo amplifier Fig.
SF1252
SF1253
A
B
MR-E-10A/AG-KH003 to MR-E-100A/AG-KH003
MR-E-200A/AG-KH003
EMC filter
The following filters are recommended as a filter compliant with the EMC directive for the servo amplifier’s power supply.
The following are examples of wire sizes when 600V polyvinyl chloride insulated wires with a length of 30m are used.
External dimensions (Unit: mm) Connections
SF1252
SF1253
LINE
(input side)
LOAD
(output side)
168.0
140.0
156.0
149.5
ø6.0
42.0
8.5
16.0
Model
SF1252
Mass kg (lb)
0.75 (1.7)
Model
SF1253
Mass kg (lb)
1.37 (3.0)
LINE
(input side)
LOAD
(output side)
209.5
168.0
140.0
156.0
8.5
23.0
49.0
ø6.0
A
B
L3
L2
L1
L3’
L2’
L1’
L3
L2
L1
Servo amplifier
LOADLINE
EMC filter
NFB
MC
(Note 2)
(Note 1)
Power supply
3-phase
200 to 230VAC
or
1-phase
230VAC
Notes: 1.
2.
When using a power supply, 1-phase 230VAC, connect the
power supply to the L1 and L2 terminals. Do not connect
anything to L3. The 1-phase 230VAC is available only for
the MR-E-70A/AG-KH003 or smaller servo amplifier.
Connect when the power supply has earth.
Electrical wires, circuit breakers and magnetic contactors
MR-E-10A/AG-KH003
MR-E-20A/AG-KH003
MR-E-40A/AG-KH003
MR-E-70A/AG-KH003
MR-E-100A/AG-KH003
MR-E-200A/AG-KH003
30A frame 5A
30A frame 5A
30A frame 10A
30A frame 15A
30A frame 15A
30A frame 20A
2 (AWG14)
2.5 (AWG14) (Note 1)
L1, L2, L3, P, C, D
2 (AWG14)
S-N10
S-N18
Circuit breaker
1.25 (AWG16)
2 (AWG14)
2.5 (AWG14) (Note 1)
U, V, W, B1, B2
1.25 (AWG16)
Magnetic contactor
Servo amplifier
Electrical wire size (mm
2
)
Notes: 1. When using AWG14 at an ambient temperature of 40°C (104°F) or more, use heat-resistant PVC (rated 105°C [221°F] or more). Refer to the specifications in this catalog for the
permissible ambient temperature of the servo amplifier and servo motor.