Instruction manual

13 - 17
13. OPTIONS AND AUXILIARY EQUIPMENT
Encoder cable of 30m or more
POINT
The communication system of the encoder cable in this wiring diagram is
the four-wire type. Set "1
" in parameter No. 20.
When fabricating an encoder cable, use the MR-ECNS (IP20-compatible model) or MR-ENECNS
(IP65/IP67-compatible model) connector set. Referring to the following wiring diagram, you can
fabricate an encoder cable of up to 50m.
MRR
P5
LG
1
2
MR 3
4
MDR 8 B
F
S
A
MD 7
9
SD
C
D
R
N
MR-ESCBL30M-H
MR-ESCBL40M-H
MR-ESCBL50M-H
MR-ENECBL30M-H
MR-ENECBL40M-H
MR-ENECBL50M-H
P5G
MR
MRR
MDR
MD
SHD
P5E
MCONT
Servo amplifier side Encoder side
Plate
(Note)
Note. When an encoder cable is fabricated, this wire is not required.