Instruction manual

15 - 7
15. MR-E-
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
(2) MR-E-200AG
L
3
L
2
L
1
DC L3PL1L2
CHARGE
CNP2
CNP1
CN1
CN2
UVW
CN3
MODE
SET
MITS U B IS H I
EZMotion
P
C
Options and auxiliary equipment
No-fuse breaker
Magnetic contactor
Servo configuration software
Regenerative option
Refer to
Section 13.2.2
Section 13.2.2
Section 13.1.4
Section 13.1.1
Options and auxiliary equipment
Refer to
Cables Section 13.2.1
Power factor improving reactor
Section 13.2.3
Power
actor
improving
reactor
(FR-BAL)
3-phase 200V
to 230VAC
power supply
No-fuse
breaker
(NFB) or
fuse
Magnetic
contactor
(MC)
To CN2
To CN1
To CN3
Servo amplifier
Regenerative option
Personal
computer
Command device
Servo configuration
software
MRZJW3-SETUP1
To CNP2