SAFETY PRECAUTIONS (Always read these precautions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".
[DESIGN PRECAUTIONS] DANGER Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is gone out. When the GOT backlight goes out, the POWER LED flickers (green/orange) and the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) remains active.
[MOUNTING PRECAUTIONS] CAUTION When loading the communication unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Overtightening can cause a drop, failure or malfunction due to the damage of the screws or unit. When mounting the multi-color display board onto the GOT, tighten the mounting screws within the specified torque range. Loose tightening may cause the unit and/or GOT to malfunction due to poor contact.
[WIRING PRECAUTIONS] CAUTION Please make sure to ground FG terminal and LG terminal of the GOT power supply section by applying Class D Grounding (Class 3 Grounding Method) or higher which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction. Be sure to tighten any unused terminal screws with a torque of 0.5 to 0.8N•m. Failure to do so may cause a short circuit due to contact with a solderless terminal.
[TEST OPERATION PRECAUTIONS] DANGER Before performing the test operations of the user creation monitor screen (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual carefully and make yourself familiar with the operation method. During test operation, never change the data of the devices which are used to perform significant operation for the system.
[STARTUP/MAINTENANCE PRECAUTIONS] CAUTION Do not disassemble or modify the unit. Doing so can cause a failure, malfunction, injury or fire. Do not touch the conductive and electronic parts of the unit directly. Doing so can cause a unit malfunction or failure. The cables connected to the unit must be run in ducts or clamped. Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
[DISPOSAL PRECAUTIONS] CAUTION When disposing of the product, handle it as industrial waste. [TRANSPORTATION PRECAUTIONS] CAUTION When transporting lithium batteries, make sure to treat them based on the transport regulations. (For details on models subject to restrictions, refer to the User's Manual for the GOT you are using.
REVISIONS * The manual number is given on the bottom left of the back cover. Print Date * Manual Number Dec., 2007 JY997D30901A Revision First edition This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
INTRODUCTION Thank you for choosing Mitsubishi Graphic Operation Terminal (Mitsubishi GOT). Read this manual and make sure you understand the functions and performance of the GOT thoroughly in advance to ensure correct use. CONTENTS SAFETY PRECAUTIONS .................................................................................................................................A - 1 REVISIONS..................................................................................................................
ABOUT MANUALS The following manuals are also related to this product. In necessary, order them by quoting the details in the tables below. Related Manuals Manual Number Manual Name (Model Code) GT15 User's Manual - Describes the GT15 hardware-relevant contents, including the specifications, part names, mounting, power SH-080528ENG supply wiring, external dimensions, and option devices. (1D7M23) - Describes the GT15 functions, including the utility.
ABBREVIATIONS AND GENERIC TERMS IN THIS MANUAL Abbreviations and generic terms used in this manual are as follows: GOT Abbreviations and generic terms GT SoftGOT1000 Abbreviation of GT SoftGOT1000 GT1595 GT1595-X Abbreviation of GT1595-XTBA, GT1595-XTBD GT1585V-S Abbreviation of GT1585V-STBA GT1585-S Abbreviation of GT1585-STBA, GT1585-STBD GT1575V-S Abbreviation of GT1575V-STBA GT1575-S Abbreviation of GT1575-STBA, GT1575-STBD GT1585 GT157 GT156 GOT1000 Series Description GT155 GT15 GT1
Option unit Abbreviations and generic terms Printer unit GT15-PRN Video input unit Video/RGB unit Description GT15V-75V4 RGB input unit GT15V-75R1 Video/RGB input unit GT15V-75V4R1 RGB output unit GT15V-75ROUT CF card unit GT15-CFCD CF card extension unit*1 GT15-CFEX-C08SET External I/O unit GT15-DIO Sound output unit GT15-SOUT *1 GT15-CFEX + GT15-CFEXIF + GT15-C08CF set.
Software Abbreviations and generic terms GT Works2 Version Description SW D5C-GTWK2-E, SW D5C-GTWK2-EV GT Designer2 Version SW D5C-GTD2-E, SW D5C-GTD2-EV GT Designer2 Abbreviation of screen drawing software GT Designer2 for GOT1000/GOT900 series GT Converter2 Abbreviation of data conversion software GT Converter2 for GOT1000/GOT900 series GT Simulator2 Abbreviation of screen simulator GT Simulator 2 for GOT1000 / GOT900 series GT SoftGOT1000 Abbreviation of monitoring software GT SoftGOT1000 G
Others Abbreviations and generic terms Description Omron PLC Abbreviation of PLC manufactured by OMRON Corporation KEYENCE PLC Abbreviation of PLC manufactured by KEYENCE Sharp PLC Abbreviation of PLC manufactured by SHARP Corporation JTEKT PLC Abbreviation of PLC manufactured by JTEKT Corporation Toshiba PLC Abbreviation of PLC manufactured by TOSHIBA CORPORATION HITACHI IES PLC Abbreviation of PLC manufactured by Hitachi Industrial Equipment Systems Co., Ltd.
HOW TO READ THIS MANUAL 1 About each of functions This manual includes information of GT Designer2 Version2.73B. For additional functions of upgraded version, refer to the List of functions added by version upgrade. 2 Symbols Following symbols are used in this manual. Connectable model name Not connectable model name Applicable model name Shows GT15. Shows GT11. Shows GT11 (BUS). Shows GT11 (SERIAL). Shows GT10. Shows GT10(input power supply : 24V). Shows GT10(input power supply : 5V).
MEMO A - 16
1 OVERVIEW 1 CONNECTION TO α2 2 OVERVIEW 1. OVERVIEW This manual describes the specifications, system configuration, setting method, connection cables and others for connecting the GOT to the α2. For applying the setting examples in this manual to the actual system, make sure that the target system has no troubles on the control. 1.1 Connection to α2 . . . . . . . . . . . . . . page 1-4 This section describes the connections and functions supported by the GOT1000 Series.
1 Relevant Manuals There are the following manuals available for use of the GOT1000 series. Refer to each manual suitable for the intended purpose. The following manuals describe that the GOT cannot connect to the α2 connection because the manuals are written for commercially available products. For referring to each manual, read the manuals so that the GOT can connect to the α2 connection.Refer to each of them according to the intended purpose.
1 OVERVIEW (2) Installing a GOT Connecting with a PLC For the operations from installing a GOT to communicating with a PLC CPU, refer to the following manuals.
1.1 Connection to α2 1 Connection to α2 The GOT can monitor devices of the α2. The following shows the system configurations for each GOT model. 2 System configuration for α2 connection The following shows the system configuration. Communication Type Communication Interface on GOT Side Connected to Model Built in GT15, GT11 and GT10 body RS-232 (RS-232) RS-232 communication 1-4 • α2 RS-232 Communication Unit • GT15-RS2-9P 1.
2 OVERVIEW 1 CONNECTION TO α2 2 CONNECTION TO α2 2. CONNECTION TO a2 2.1 System Configuration . . . . . . . . . . page 2-2 This section describes the equipment and cables needed when connecting a GOT to an α2. Select a system suitable for your application. 2.2 Connection Cable . . . . . . . . . . . . . page 2-4 This section describes the specifications of the cables needed when connecting to an α2. Check the specifications of the connection cables. 2.3 Preparatory Procedures for Monitoring . . .
2.1 System Configuration Select a system configuration suitable for your application. Conventions used in this section Numbers (e.g. ) of to the numbers (e.g. System configuration and connection conditions correspond ) of System equipment. Use these numbers as references when confirming models and applications. 2.1.1 When connecting to AL2-14MR, AL2-24MR Communication driver ALPHA2 1 System configuration and connection conditions Connection conditions No.
1 2 System equipment No. RS-232 Name Model name RS-232 interface • For RS-232 communication Model 2 (Built into GOT) (RS-232) RS-232 RS-232 Communication Unit • For RS-232 communication GT15-RS2-9P (2) Cable Image No. Name RS-232 interfaca cable Model name Model AL2-GSM-CAB (RS-232) RS-232 cable 1) • Between CPU, RS-232C adapter and connection cable (To be prepared by the user. Section 2.2 Connection Cable) RS-232 cable 2) • Between RA232C interface cable and GOT (RS-232) 2.
2.2 Connection Cable The RS-232 cable used for connecting the GOT to the α2 should be prepared by the user. The following provides connection diagrams for each cable, connector specifications and other information. Connection cable GT15, GT11 Model AL2-14MR- α2 GT10 RS-232 cable RS-232 cable (See Section 2.2.1) (See Section 2.2.1) RS-232 cable 1) RS-232 cable 2) AL2-24MR- 2.2.
1 (1) GOT side connector Use the following as the RS-232 interface and RS-232 communication unit connector on the GOT. For the GOT side of the RS-232 cable, use a connector or connector cover applicable to the GOT connector.
2.3 Preparatory Procedures for Monitoring The following the procedures to be taken before monitoring and corresponding reference sections. Install the OS onto the GOT. Section 2.3.1 Installing OS onto GOT Make sure that the OS is installed on the GOT. 2.3.1 Installing OS onto GOT Install the standard monitor OS, communication driver and option OS onto the GOT. For the OS installation methods, refer to the following manual. GT Designer2 Version Transfer Manual Basic Operation/Data Section 2.3.
Check if the OS is properly installed or not on the Drive information tab of GT Designer2. For the operation on the Drive information tab, refer to the following manual. GT Designer2 Version Transfer Manual Basic Operation/Data 2.3.3 1 Setting communication interface (Communication settings) OVERVIEW Checking OS installation on GOT Make the GOT communication interface settings on [Communication Settings] of GT Designer2.
2.3.4 Downloading project data 2.3.5 Attaching communication unit and connecting cable Download project data to the GOT. For how to download project data, refer to the following manual. GT Designer2 Version Transfer Manual Basic Operation/Data Cautions when attaching the communication unit and connecting the cable Shut off all phases of the GOT power supply before attaching the communication unit and connecting the cable.
1 (c) For the GT10 (built-in RS-232 interface) 2 How to connect the cable (a) For the GT15 • connection to the RS-232 interface OVERVIEW 1 Connect the RS-232 cable to the terminal block packed together with the GOT. (1) How to connect the RS-232 cable 1 Connect the RS-232 cable to the RS-232 interface on the GOT. CONNECTION TO α2 2 2 Connect the terminal block to the GOT. • connection to the RS-232 communication unit 1 Connect the RS-232 cable to the RS-232 communication unit on the GOT.
2.3.6 Verifying GOT recognizes controllers Verify the GOT recognizes controllers on [Communication Settings] of the Utility.
2.3.7 1 Checking for normal monitoring (2) For GT10 (a) Communication interface setting by the Utility Although the communication interface setting can be checked, it cannot be changed. For details on the Utility, refer to the following manual. GT10 User's Manual (b) Communication settings Communication settings can be changed on only GT Designer2.
2 Perform an I/O check (for GT15, GT11) Whether the PLC can communicate with the GOT or not can be checked by the I/O check function. If this check ends successfully, it means correct communication interface settings and proper cable connection. Display the I/O check screen by [Main Menu] [Debug & self check] [Self check] [I/O check].
1 4 Confirming the PLC side setting OVERVIEW When connecting the GOT, setting is required for the PLC side. Confirm if the PLC side setting is correct. Section 2.4 PLC Side Setting 2 All settings related to communications are complete now. CONNECTION TO α2 Create screens on GT Designer2 and download the project data again. 2.3 Preparatory Procedures for Monitoring 2.3.
2.4 PLC Side Setting α2 For details of α2, refer to the following manuals. COMMUNICATION MANUAL α2 SIMPLE APPLICATION CONTROLLER PROGRAMMING MANUAL α2 SIMPLE APPLICATION CONTROLLER 2.4.1 Communication setting Make the communication settings by front panel key or AL-VLS/WIN-E. Item Setting Modem other Data Bit 8 Parity None Stop Bit 1 Baud Rate 9600 2 - 14 2.4 PLC Side Setting 2.4.
1 2.5 Device Range Available for GOT1000 Series Device range available for GOT1000 series OVERVIEW 2.5.1 The device ranges of α2 that can be used for GOT are as follows. 2 CONNECTION TO α2 Note that the device ranges in the following tables are the maximum values that can be set in GT Designer2. Please make setting according to the specifications of the controller actually used. When a non-existent device or device No. outside the range is specified, other objects may not be monitored.
2.6 List of Functions Added by Version Upgrade The following describes the function added by version upgrade of GT Designer2 or OS. For using the function below, use the GT Designer2 or OS of the stated version or later. Model Item Description Version of GT Designer2 Version of OS Communication driver ALPHA2 [03.10.**] α2 connection Supporting connection to α2 2.73B Standard monitor OS [01.07.**] Communication driver ALPHA2 [01.00.**] 2 - 16 2.
WARRANTY Please confirm the following product warranty details before using this product. 1. Gratis Warranty Term and Gratis Warranty Range If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company.
Microsoft Windows, Microsoft Windows NT, Windows Vista are registered trademarks of Microsoft Corporation in the United States and other countries. Adobe and Adobe Reader are registered trademarks of Adobe Systems Incorporated. Pentium and Celeron are a registered trademarks of Intel Corporation in the United States and other countries. Ethernet is a trademark of Xerox Co., Ltd. in the United States. MODBUS is a trademark of Schneider Electric SA.