Charging Timer is
not possible.
After the power/com-
munication switch is
pressed, the following
symbol blinks in sev-
eral seconds.
ERROR symbol
symbol
Regular charge connector is not inserted
or not locked completely.
Lock the regular charge connector securely.
A household electrical outlet, which the
EV charging cable (regular charger) is
connected to, is shut down.(e.g. discon-
nected plug)
Turn on the household electrical outlet which the
EV charging cable (regular charger) is connected
to.
Ground fault at the household electrical
outlet. Otherwise, the power supply at
the household electrical outlet is cut off.
Check the ground fault and confirm the plug is
connected.
If the charging unit is equipped with the
timer function, the power supply to the
unit has been cut off.
Preset the Charging Timer while the charging
unit with timer function is powered on.
After the power/com-
munication switch is
pressed, the following
symbol blinks in sev-
eral seconds.
ERROR symbol
The selector lever is at a position other
than P (PARK).
Place the selector lever to P (PARK) position.
Quick charging is in progress. (if so
equipped) (The symbol illumi-
nates.)
Terminate the quick charging, or wait until the
quick charging completes.
The temperature of the Main Drive Lith-
ium-ion Battery has exceeded about
140 °F (60 °C).
Allow the temperature of the Main Drive Lith-
ium-ion Battery to reach normal operating tem-
perature. Refer to “Cautions and action to deal
with intense heat” on page 1-10.
The temperature of the Main Drive Lith-
ium-ion Battery has been under about -
13 °F (-25 °C).(except vehicles with
Main Drive Lithium-ion Battery Warm-
ing System)
Allow the temperature of the Main Drive Lith-
ium-ion Battery to reach normal operating tem-
perature. Refer to “Cautions and action to deal
with intense cold” on page 1-12.
Phenomena Cause Remedy
BK0140800US.book 69 ページ 2011年9月29日 木曜日 午後3時28分