Operation Manual

General information/Charging
1-71
1
Timed charging is
impossible.
It is not fully charged. If the charging unit is equipped with the
timer function, the power supply to the
unit has been cut off.
Preset the Charging Timer while the charging
unit with timer function is powered on.
The Remote Cli-
mate Control can-
not be activated.
After the power/com-
munication switch is
pressed, the following
symbol blinks in sev-
eral seconds.
ERROR symbol
symbol
The regular charge connector is not
inserted or it is not locked completely.
Lock the regular charge connector securely.
A household electrical outlet, which the
EV charging cable (regular charge) is
connected to, is shut down.(e.g. discon-
nected plug)
Turn on the household electrical outlet which the
EV charging cable (regular charge) is connected
to.
Ground fault at the household electrical
outlet. Otherwise, the power supply at
the household electrical outlet is cut off.
Check the ground fault and confirm the plug is
connected.
If the charging unit is equipped with the
timer function, the power supply to the
unit has been cut off.
Preset the Charging Timer while the charging
unit with timer function is powered on.
After the power/com-
munication switch is
pressed, the following
symbol blinks in sev-
eral seconds.
ERROR symbol
symbol
The Main Drive Lithium-ion Battery
charging level is low.
Charge the Main Drive Lithium-ion Battery until
the MiEV Remote illuminates the battery charg-
ing level by at least 1 segment.
Phenomena Cause Remedy
BK0140800US.book 71 ページ 2011年9月29日 木曜日 午後3時28分