Operation Manual

1-72
General information/Charging
1
The Remote Cli-
mate Control can-
not be activated.
After the power/com-
munication switch is
pressed, the following
symbol blinks in sev-
eral seconds.
ERROR symbol
Any of the door or liftgate is open. Close all the doors and liftgate.
The selector lever is at the position other
than P (PARK).
Place the selector lever to P (PARK) position.
Quick charging is in progress. (if so
equipped)
(The symbol will illuminate.)
Terminate the quick charging, or wait until the
quick charging completes.
The temperature of the Main Drive Lith-
ium-ion Battery has exceeded about
140 °F (60 °C).
Allow the temperature of the Main Drive Lith-
ium-ion Battery to reach normal operating tem-
perature. Refer to “Cautions and action to deal
with intense heat” on page 1-10.
The temperature of the Main Drive Lith-
ium-ion Battery has been under about -
13 ° F (-25 °C). (except vehicles with
Main Drive Lithium-ion Battery Warm-
ing System)
Allow the temperature of the Main Drive Lith-
ium-ion Battery to reach normal operating tem-
perature. Refer to “Cautions and action to deal
with intense cold” on page 1-12.
The Remote Climate
Control is not activated.
The electric motor switch has been
operated before the system is charged.
Check whether the electric motor switch has
been operated before the system is charged.
The temperature of the Main Drive Lith-
ium-ion Battery has exceeded about
140 °F (60 °C).
Allow the temperature of the Main Drive Lith-
ium-ion Battery to reach normal operating tem-
perature. Refer to “Cautions and action to deal
with intense heat” on page 1-10.
The temperature of the Main Drive Lith-
ium-ion Battery has been under about -
13 ° F (-25 °C). (except vehicles with
Main Drive Lithium-ion Battery Warm-
ing System)
Allow the temperature of the Main Drive Lith-
ium-ion Battery to reach normal operating tem-
perature. Refer to “Cautions and action to deal
with intense cold” on page 1-12.
Phenomena Cause Remedy
BK0140800US.book 72 ページ 2011年9月29日 木曜日 午後3時28分