CHAPTER 4 FUNCTION
4
4.3 Comparison Output Function
4.3.4 Cam switch function
(3) Output range setting
With the cam switch setting, the maximum of 16 steps of ON/OFF switching can be set per one output point.
The part where the ON/OFF signal status is switched is referred to as a step.
A setting example with the coincidence output 1 is shown below.
For signals applied to coincidence output 2 to 8, refer to the following section.
Page 32, Section 3.3.1
For buffer memory addresses applied to coincidence output 2 to 8, refer to the following section.
Page 42, Section 3.4.1
Cam switch function, step type (coincidence output 1) (Un\G200) is set to OFF, and Cam switch function,
number of steps (coincidence output 1) (Un\G201) is set to 6
Setting item Setting contents Reference
Cam switch function, step type
(coincidence output 1) (Un\G200)
Set the ON/OFF status of Coincidence output 1 (X10) at the
time when the pulse counting starts.
Page 68, Section 3.4.2 (8)
Cam switch function, number of steps
(coincidence output 1) (Un\G201)
Set the number of steps for the coincidence output 1. Page 68, Section 3.4.2 (9)
Cam switch function, step No.1 to No.16
setting (coincidence output 1) (Un\G202 to
Un\G233)
Set the count value where the ON/OFF status of Coincidence
output 1 (X10) is to be switched.
Page 69, Section 3.4.2 (10)
Setting item Setting value
Cam switch function, step type (coincidence output 1) (Un\G200) 0
Cam switch function, number of steps (coincidence output 1) (Un\G201)) 6
Cam switch function, step No.1 setting (coincidence output 1) (Un\G202 to Un\G203) 100
Cam switch function, step No.2 setting (coincidence output 1) (Un\G204 to Un\G205) 250
Cam switch function, step No.3 setting (coincidence output 1) (Un\G206 to Un\G207) 400
Cam switch function, step No.4 setting (coincidence output 1) (Un\G208 to Un\G209) 550
Cam switch function, step No.5 setting (coincidence output 1) (Un\G210 to Un\G211) 700
Cam switch function, step No.6 setting (coincidence output 1) (Un\G212 to Un\G213) 850
Cam switch function, step No.7 setting (coincidence output 1) (Un\G214 to Un\G215)
Setting not necessary
•••
Cam switch function, step No.16 setting (coincidence output 1) (Un\G232 to Un\G233)
Ex.
ON
OFF
123
4
56
100 250 400 550 750 850
Step No.
CH1 Present value
(Un\G1050, Un\G1051)
Coincidence output 1
(X10) or coincidence
output 1 terminal
(EQU1)