The present values are not replaced with the preset values while CH1 External preset/replace (Z phase) request
detection (X05) is ON.
To avoid that, turn on CH1 External preset/replace (Z phase) request detection reset command (Y05) and turn off CH1
External preset/replace (Z phase) request detection (X05) before executing the preset/replace function.
The values set to CH1 Preset value (Un\G1014, Un\G1015) are enabled with up to 2ms delay. So when you execute the