CHAPTER 4 FUNCTION
4
4.14 Rotation Speed Measurement Function
Number Description
1)
Perform the following operations when CH1 Count enable command (Y06) is turned on:
• Latch the values in CH1 Time unit setting (rotation speed measurement) (Un\G1150), CH1 Moving average count (rotation
speed measurement) (Un\G1151), and CH1 Number of pulses per rotation (Un\G1152, Un\G1153). (The change of the
setting values during the rotation speed measurement is ignored.)
• Reset CH1 Measured rotation speed value update flag (Un\G1181) to 0
H
: Not updated.
• Clear the values in CH1 Measured rotation speed value (Un\G1182, Un\G1183) to 0.
Also, 1
H
: Operating is stored in CH1 Rotation speed measurement flag (Un\G1180) when CH1 Count enable command (Y06) is
turned on.
2)
The following operation is performed when the measured value of the rotation speed is stored in CH1 Measured rotation speed
value (Un\G1182, Un\G1183):
•1
H
: Updated is stored in CH1 Measured rotation speed value update flag (Un\G1181).
3)
Reset CH1 Measured rotation speed value update flag (Un\G1181) to 0
H
: Not updated by setting CH1 Measured rotation speed
value update flag reset command (Un\G1170) to 1
H
: Reset.
CH1 Measured rotation speed value update flag reset command (Un\G1170) is automatically reset to 0
H
: Not reset after the
completion of the reset.
4)
CH1 Measured rotation speed value (Un\G1182, Un\G1183) is updated when 1
H
: Updated is stored in CH1 Measured rotation
speed value update flag (Un\G1181).
5)
0
H
: Not operating is stored in CH1 Rotation speed measurement flag (Un\G1180) by turning off CH1 Count enable command
(Y06).