(5) Requirements for compliance with the EMC and Low Voltage Directives
Take the following measures to comply the system with the EMC and Low Voltage Directives.
Install the DC power connected to the encoder inside the same control panel as the QD65PD2.
Be sure to attach ferrite cores to the DC power cables to be connected to the QD65PD2 and the controller.
The ferrite core ZCAT3035-1330 (manufactured by TDK Corporation) is recommended.
Keep the length of the cables between the QD65PD2 and the encoder to 3m or less.
Keep the length of the cables between the QD65PD2 and the controller or external output to 30m or less.
Keep the length of the DC power cables to be connected to external devices for the QD65PD2 to 3m or less.
Use a shielded twisted pair cable and ground the shielded part of the cable to the control panel with the
AD75CK-type cable clamp (Mitsubishi).
For details on the AD75CK, refer to the following manual.
AD75CK-type Cable Clamping Instruction Manual
QD65PD2
20 to 30cm
Inside the control panel
AD75CK