CHAPTER 6 SETTINGS
6
6.1 Adding a Module
CHAPTER 6 SETTINGS
This chapter describes how to specify the QD65PD2 settings.
● To activate module settings, parameter settings, and auto refresh settings, write the settings to the CPU module. Then,
reset the CPU module, switch the operating status of the CPU module as follows: STOP, RUN, STOP, and RUN, or power
off and on the system.
● To activate switch settings, write the settings to the CPU module. Then, reset the CPU module or power off and on the
system.
● Keep the intelligent function module detailed setting as the default.
"Error Time Output Mode" and "PLC Operation Mode at H/W Error" on the intelligent function module detailed setting are
always "Clear" and "Stop". If those other than these are set, an error (error code: 800) occurs.
6.1 Adding a Module
Add the model name of the QD65PD2 to be used in the project.
(1) How to add a module
Open "New Module".
Project window [Intelligent Function Module] right-click [New Module]
Item Description
Module Selection
Module Type Set "Counter Module".
Module Name Select the model name of the module to be connected.
Mount Position
Base No. Set the base unit where the module is mounted.
Mounted Slot No. Select the number of the slot where the module is mounted.
Specify start XY
address
The start I/O number (hexadecimal) of the module to be mounted on the slot
set in "Mounted Slot No." is displayed. Any number can be set.
Title Setting Title Set any title.