User`s manual

181
CHAPTER 6 SETTINGS
6
6.2 Switch Setting
*1 When connected with DC input, set counting speed to 200kpps or slower.
*2 When the function input logic setting and the latch counter input logic setting are set to negative logic, the OFF ON
response time and the ON OFF response time invert.
For example, when 0 is set, the OFF ON response time is 0.1ms, and the ON OFF response time is 0.02ms.
Pulse input mode Set the pulse input mode for each channel.
• 0: 1-Phase Multiple of 1
• 1: 1-Phase Multiple of 2
• 2: CW/CCW
• 3: 2-Phase Multiple of 1
• 4: 2-Phase Multiple of 2
• 5: 2-Phase Multiple of 4
Counting speed setting
*1
Set the counting speed for each channel.
• 0: 10kpps
• 1: 100kpps
• 2: 200kpps
• 3: 500kpps
• 4: 1Mpps
• 5: 2Mpps
• 6: 4Mpps
• 7: 8Mpps
Counter format
Select the linear counter or the ring counter
for each channel.
• 0: Linear Counter
• 1: Ring Counter
Function input logic setting Set the function input logic for each channel
• 0: Positive Logic
• 1: Negative Logic
Latch counter input logic setting
Set the latch counter input logic for each
channel
• 0: Positive Logic
• 1: Negative Logic
Counter function selection
Select the counter function activated when
the operation mode setting of each channel
is the normal mode.
• 0: Count Disabling Function
• 1: Latch Counter Function
• 2: Sampling Counter Function
• 3: Periodic Pulse Counter Function
• 4: Count disable/Preset/replace Function
• 5: Latch counter/Preset/replace Function
Z phase input response time
setting
Set the response time of the phase Z input
signal for each channel.
• 0: OFF ON Response time 0.25µs, ON OFF
Response time 2.5µs
• 1: OFF ON Response time 0.1ms, ON OFF
Response time: 0.1ms
• 2: OFF ON Response time 1.0ms, ON OFF
Response time 1.0ms
Function input response time
setting
*2
Set the response time of the function input
signal for each channel.
• 0: OFF ON Response time 0.02ms, ON OFF
Response time 0.1ms
• 1: OFF ON Response time 0.1ms, ON OFF
Response time 0.1ms
• 2: OFF ON Response time 1.0ms, ON OFF
Response time 1.0ms
Latch counter input response time
setting
*2
Set the response time of the latch counter
input signal for each channel.
• 0: OFF ON Response time 0.02ms, ON OFF
Response time 0.1ms
• 1: OFF ON Response time 0.1ms, ON OFF
Response time 0.1ms
• 2: OFF ON Response time 1.0ms, ON OFF
Response time 1.0ms
Item Description Setting value