User`s manual
184
(b) Combination availability by count source selection and the pulse input mode
*1 If this is set, an error occurs (error code: 812 or 814, The channel where the error has occurred is stored in ).
Pulse input mode (all) Counting speed setting (all)
Count source
selection
0: A Phase/B Phase
1: Internal Clock
(0.1µs)
2: Internal Clock (1µs)
3: Internal Clock
(10µs)
4: Internal Clock
(100µs)
5: Coincidence output
1
6: Coincidence output
2
: Available, : Setting ignored
Counting speed setting
0:
10kpps
1:
100kpps
2:
200kpps
3:
500kpps
4:
1Mpps
5:
2Mpps
6:
4Mpps
7:
8Mpps
Pulse input
mode
0: 1-Phase Multiple of
1
×
*1
×
*1
1: 1-Phase Multiple of
2
×
*1
2: CW/CCW
×
*1
×
*1
3: 2-Phase Multiple of
1
×
*1
×
*1
4: 2-Phase Multiple of
2
×
*1
5: 2-Phase Multiple of
4
: Available, ×: Unavailable (Error)