200
(3) Auto refresh setting
Set the target device for auto refresh.
Project window [Intelligent Function Module] [QD65PD2] [Auto_Refresh]
Item Description Setting value
Counter value greater/smaller (coincidence
output)
*1
stores the relationship (greater or smaller) between the point
setting of coincidence output 1 to 8 and the present value.
D16
Error status Set the device that stores the error status of each channel. D32
Warning status Set the device that stores the warning status of each channel. D35
Present value Set the device that stores the present value. D0
Latch count value *2
Set the device that stores the latch count value when the latch
counter function (counter function selection) is used.
D2
Latch count value (latch counter input
terminal)
*3
Set the device that stores the latch count value by the latch
counter input terminals (LATCH1, LATCH2).
D4
Sampling count value *4
Set the device that stores the sampling count value when the
sampling counter function is used.
D6
Periodic pulse count, difference value
*5
Set the device that stores the periodic pulse count difference
value when the periodic pulse counter function is used.
D8
Periodic pulse count, present value
Set the device that stores the periodic pulse count present
value when the periodic pulse counter function is used.
D10
Periodic pulse count value update check
Set the device that stores the periodic pulse count update
check value when the periodic pulse counter function is used.
D12
Overflow/underflow detection flag
Set the device that stores the detected result of overflow/
underflow error when the linear counter function is used.
D14
Measured frequency value *6
Set the device that stores the periodic pulse count value when
the periodic pulse counter function is used.
D44
Measured rotation speed value *7
Set the device that stores the measured value of the rotation
speed when the rotation speed measurement function is used.
D54
Measured pulse value (function input
terminal)
*8
Set the device to store the measured pulse value of the
function input terminal when a pulse measurement function is
used.
D62
Measured pulse value (latch counter input
terminal)
Set the device to store the measured pulse value of the latch
counter input terminal when a pulse measurement function is
used.
D72