User`s manual

207
CHAPTER 7 PROGRAMMING
7
7.1 Using the Module in a Standard System Configuration
7.1.2 Program example when the parameters of the intelligent function module are not used
(2) Program example under the normal mode
(a) Initial setting program
*1 Set only when using the coincidence output function.
*2 Set only when using the cam switch function.
*3 Set only when using the ring counter function.
*4 Set only when using the sampling counter function or periodic pulse counter function.
Coincidence output comparison condition
setting
coincidence output 1: coincidence output
coincidence output 2: in-range output
Preset/replace setting at coincidence
output: Not preset
Point setting (coincidence output 1)
: 1000
Lower limit value request (coincidence
output 2): 1000
Upper limit value request (coincidence
output 2): 2000
CH1 Phase Z setting
: ON at detection, Rising
CH1 Ring counter lower limit value
: -5000
CH1 Ring counter upper limit value
: 5000
CH1 Preset value setting: 100
CH1 Cycle setting (sampling counter/
periodic pulse counter): 2000ms
CH1 Time unit setting (sampling
counter/periodic pulse counter): 1ms
Turn on Operating condition settings
batch-change command.
Turn off Operating condition settings
batch-change command.
Cam switch function, step type
(coincidence output 1): Start from output
status OFF
Cam switch function, number of steps
(coincidence output 1): 6
Cam switch function, step No.1
(coincidence output 1): 100
Cam switch function, step No.2
(coincidence output 1): 250
Cam switch function, step No.3
(coincidence output 1): 400
Cam switch function, step No.4
(coincidence output 1): 550
Cam switch function, step No.5
(coincidence output 1): 700
Cam switch function, step No.6
(coincidence output 1): 850
*1
*2
*3
*4