User`s manual
217
CHAPTER 7 PROGRAMMING
7
7.2 When Using the QD65PD2 in a MELSECNET/H Remote I/O net
4. The following dialog box will be displayed.
Click the button.
5. Open the switch setting dialog box for the QD65PD2 and set parameters as shown below.
Project window [Intelligent Function Module] [QD65PD2] [Switch Setting]
Item Setting value
Comparison output setting value Set comparison output depending on the program example to be used.
Coincidence output 1 channel assignment setting CH1
Coincidence output 2 channel assignment setting CH1
Coincidence output 3 channel assignment setting
Setting is not necessary for the program examples in this chapter.
•••
Coincidence output 8 channel assignment setting
Operation mode setting Set operation mode depending on the program example to be used.
Count source selection A Phase/B Phase
Pulse input mode 2-Phase Multiple of 1
Counting speed setting 200kpps
Counter format Set a counter format depending on the program example to be used.
Function input logic setting Positive Logic
Latch counter input logic setting Positive Logic
Counter function selection Set a counter function depending on the program example to be used.
Z phase input response time setting
Set any response time.Function input response time setting
Latch counter input response time setting