User`s manual

222
*1 Set only when using the coincidence output function.
*2 Set only when using the latch counter function (counter function selection).
*3 Set only when using the latch counter function by latch counter input terminal.
*4 Set only when using the sampling counter function or periodic pulse counter function.
*5 Set only when using the periodic pulse counter function.
*6 Set only under the frequency measurement mode.
*7 Set only under the rotation speed measurement mode.
*8 Set only under the pulse measurement mode.
8. Write the set parameter data to the remote I/O module and reset the remote I/O module.
Measured pulse value (function input
terminal)
*8
Set the device to store the measured pulse value of the
function input terminal when a pulse measurement function is
used.
W62
Measured pulse value (latch counter input
terminal)
Set the device to store the measured pulse value of the latch
counter input terminal when a pulse measurement function is
used.
W72
Latest error code Stores the error code of the error in process. W33
Latest warning code Stores the warning code of the warning in process. W36
Item Description Setting value
MODE
RESET
Press the switch
for a while.