User`s manual
224
X1020 Module ready
QD65PD2(X/Y1020 to X/Y103F)
X1021
Operating condition settings batch-changed
signal
X1028
CH1 Cam switch function execution/PWM
output signal
X1030 Coincidence output 1 signal
X1031 Coincidence output 2 signal
Y1022 CH1 Coincidence output enable command
Y1023 Preset/replace command
Y1026 CH1 Count enable command
Y1027
CH1 Selected counter function start
command
Y1028
CH1 Cam switch function/PWM output start
command
Y1030 Reset command (coincidence output 1)
X20 Count start signal
QX10(X20 to X2F)
X22 Allow coincidence output signal
X23 Preset/replace command signal
X24 Count stop signal
X25 Coincidence LED clear signal
X26 Count disable start signal
X27 Count disable stop signal
X29 Latch counter start signal
X2B Sampling counter start signal
X2D Periodic pulse counter start signal
X2E Cam switch start signal
X32 Frequency measurement start signal
QX10(X30 to X3F)
X33 Frequency measurement stop signal
X34 Rotation speed measurement start signal
X35 Rotation speed measurement stop signal
X36
Pulse measurement (function input terminal)
start signal
X37
Pulse measurement (latch counter input
terminal) start signal
X38
Pulse measurement (function input terminal)
stop signal
X39
Pulse measurement (latch counter input
terminal) stop signal
X3A PWM output start signal
X3B Error/warning reset command signal
Y40
LED signal for checking the coincidence
output 1
QY10(Y40 to Y4F)
Y41
LED signal for checking the coincidence
output 2
Y42 LED signal for checking underflow occurrence
Y43 LED signal for checking overflow occurrence
Y44
LED signal for checking that PWM output is in
process
Device Description