A
Appendix 2 When Using GX Developer
Appendix 2.1 Operation of GX Developer
*2 When connected with DC input, set this to 200kpps or slower.
Switch
No.
Switch setting Setting item and setting value
Default
value
Switch 2
(CH1)
10) Operation mode setting
0
H
: Normal Mode
1
H
: Frequency Measurement Mode
2
H
: Rotation Speed Measurement Mode
3
H
: Pulse Measurement Mode
4
H
: PWM Output Mode
0000
H
11) Count source selection
0
H
: A Phase/B Phase
1
H
: Internal Clock (0.1µs)
2
H
: Internal Clock (1µs)
3
H
: Internal Clock (10µs)
4
H
: Internal Clock (100µs)
5
H
: Coincidence Output 1
6
H
: Coincidence Output 2
12) Pulse input mode
0
H
: 1-Phase Multiple of 1
1
H
: 1-Phase Multiple of 2
2
H
: CW/CCW
3
H
: 2-Phase Multiple of 1
4
H
: 2-Phase Multiple of 2
5
H
: 2-Phase Multiple of 4
13) Counting speed setting
*2
0
H
: 10kpps
1
H
: 100kpps
2
H
: 200kpps
3
H
: 500kpps
4
H
: 1Mpps
5
H
: 2Mpps
6
H
: 4Mpps
7
H
: 8Mpps
H