User`s manual

40
(5) CH1 External preset/replace (Z Phase) request detection reset command (Y05)
Tune on this signal to turn off CH1 External preset/replace (Z Phase) request detection (X05).
A count value cannot be replaced with the preset value while CH1 External preset/replace (Z Phase) request
detection (X05) is ON.
For details on the preset/replace operation, refer to the following:
Page 35, Section 3.3.2 (3)
(6) CH1 Count enable command (Y06)
Turn on this signal to count pulses.
The count is done as below in 1 multiple of 1 phase.
(7) CH1 Selected counter function start command (Y07)
Turn on this signal to perform the selected counter functions.
The count is done as below with the latch counter function being selected.
(8) CH1 Cam switch function/PWM output start command (Y08)
Turn on this signal to execute the cam switch function.
Turn on this signal to start PWM output.
A
B
CH1 Count enable command
(Y06)
CH1 Present value
(Un\G1050, Un\G1051)
ON
210
*1 t 2ms
031
CH1 Selected counter
function start command
(Y07)
04123
t *1 t *1
Operation by the QD65PD2
OFF
ON
OFF
ON
CH1 Present value
(Un\G1050, Un\G1051)
CH1 Latch count value
(Un\G1052, Un\G1053)