User`s manual
41
CHAPTER 3 SPECIFICATIONS
3
3.3 I/O Signals to the CPU Module
3.3.3 Details on output signals
(9) Reset command (coincidence output 1 to 8) (Y10 to Y17)
• Turn on this signal to turn off Coincidence output 1 to 8 (X10 to X17).
• This signal is enabled on the condition that Coincidence output is selected while the coincidence output
function is activated as shown below.
(10)General output 1 to 8 (Y18 to Y1F)
• This signal is used to set the values that are output from the general output 1 to 8 terminals (OUT1 to OUT8)
for external output.
• Signals are output from the general output 1 to 8 terminals (OUT1 to OUT8) for external output by turning on
this signal.
*1 t 2ms
Point setting (coincidence output 1)
(Un\G100, Un\G101)
CH1 Present value
(Un\G1050, Un\G1051)
Reset command (coincidence output 1)
(Y10)
Coincidence output 1
(X10)
t *1 t *1 t *1
0 1 999 1000
0 1000
1001
OFF
ON
OFF
ON
Operation by the QD65PD2