User`s manual

71
CHAPTER 3 SPECIFICATIONS
3
3.4 Buffer Memory Assignment
3.4.2 Details of the buffer memory
(15)CH1 Phase Z setting (Un\G1000)
Use this memory to set the trigger condition to replace a count value with the preset value using the phase Z
input terminal (Z1).
Set whether to turn on CH1 External preset/replace (Z Phase) request detection (X05) when replacing a
count value by the phase Z input terminal (Z1).
When Z phase (Preset) trigger setting is ON, External preset/replace (Z Phase) request detection setting is
disabled and CH1 External preset/replace (Z Phase) request detection (X05) remains off.
The setting values are enabled by turning off and on Operating condition settings batch-change command
(Y01).
The default values for External preset/replace (phase Z) request detection setting and Phase Z (preset/
replace) trigger setting are 0: The signal turns on when the preset/replace function is performed and 0: Rise
respectively.
(16)CH1 Periodic interrupt setting (Un\G1001)
Use this memory to select whether the periodic interrupt function is executed or not and set the values of
either 1
H
: Interrupt or 0
H
: Not interrupt.
For details on corresponding interrupt factors, refer to the following:
Page 139, Section 4.9.1
Assign the interrupt factors to interrupt pointers in the CPU module before executing the periodic interrupt
function. Failure to do so may cause an error in the CPU module.
The setting values are enabled by turning off and on Operating condition settings batch-change command
(Y01).
The default value is 0
H
: Not interrupt.
(17)CH1 Ring counter lower limit value (Un\G1010, Un\G1011)
Use these memories to set the lower limit value of the count range when the ring counter is selected for a
counter format.
Set the upper limit value of the ring counter as well.
The setting range is between -2147483648 and 2147483647 in 32-bit signed binary format.
The setting values are enabled by turning off and on Operating condition settings batch-change command
(Y01) or CH1 Count enable command (Y06).
The default value is 0.
b15
0
b14
0
b13
0
b12
0
b11
0
b10
0
b9
0
b8
0
b7
0
b6
0
b5
0
b4 b3
0
b2
0
b1 b0
Fixed to 0.
Fixed to 0.
(a) External preset/replace (Z Phase)
request detection setting
0: The signal turns on when the preset/
replace function is performed.
1: The signal remains off when the
preset/replace function is performed.
(b) Z phase (Preset) trigger setting
0: Rise
1: Fall
2: Rise + Fall
3: ON
(a)
(b)