User`s manual

77
CHAPTER 3 SPECIFICATIONS
3
3.4 Buffer Memory Assignment
3.4.2 Details of the buffer memory
(34)CH1 Selected counter function (Un\G1070)
This memory stores the values indicating the selected counter functions.
The stored value is not cleared to 0 when Operating condition settings batch-change command (Y01) is
turned off and on, and the value remains the same.
(35)CH1 Sampling counter/periodic pulse counter operation flag (Un\G1071)
This memory stores the values indicating the operation status of the sampling counter function or the
periodic pulse counter function.
The stored value is cleared to 0 by turning off and on Operating condition settings batch-change command
(Y01).
Function Value to be stored
Count disable function
0
H
Latch counter function
1
H
Sampling counter function
2
H
Periodic pulse counter function
3
H
Count disable/preset/replace function
4
H
Latch counter/preset/replace function
5
H
Operation status Value to be stored
Not operating
0
H
Operating
1
H