(48)CH1 Moving average count (rotation speed measurement) (Un\G1151)
Use this memory to set the number of moving average count for the rotation speed measurement.
The setting range is between 1 and 100. When 1 is set to CH1 Moving average count (rotation speed
measurement) (Un\G1151), the operation is performed with the moving average count regarded as not being
done.
The setting value is enabled by turning off and on CH1 Count enable command (Y06).
The default value is 1.
(49)CH1 Number of pulses per rotation (Un\G1152, Un\G1153)
Use these memories to set the number of pulses per rotation.
The setting range is between 1 and 8000000.
The setting value is enabled by turning off and on CH1 Count enable command (Y06).
The default value is 1.
(50)CH1 Measured rotation speed value update flag reset command (Un\G1170)
Use this memory to reset CH1 Measured rotation speed value update flag (Un\G1181).
CH1 Measured rotation speed value update flag (Un\G1181) is reset by setting CH1 Measured rotation
speed value update flag reset command (Un\G1170) to 1
H
: Reset. CH1 Measured rotation speed value
update flag reset command (Un\G1170) is automatically reset to 0
H
: Not reset after the reset is completed.
The default value is 0
H
: Not reset.
(51)CH1 Rotation speed measurement flag (Un\G1180)
This memory stores the value indicating whether the module is measuring the rotation speed or not.
When the module is measuring the speed, 1
H
is stored. When the module is not measuring the speed, 0
H
is
stored.
The stored value is cleared to 0 by turning off and on Operating condition settings batch-change command
(Y01).