User`s manual

83
CHAPTER 3 SPECIFICATIONS
3
3.4 Buffer Memory Assignment
3.4.2 Details of the buffer memory
(52)CH1 Measured rotation speed value update flag (Un\G1181)
This memory stores the value indicating whether CH1 Measured rotation speed value (Un\G1182,
Un\G1183) are updated or not.
When the memories are updated, 1
H
is stored. When the memories are not updated, 0
H
is stored.
CH1 Measured rotation speed value (Un\G1182, Un\G1183) are updated without resetting CH1 Measured
rotation speed value update flag (Un\G1181).
To check the update status of CH1 Measured rotation speed value (Un\G1182, Un\G1183) once again, reset
CH1 Measured rotation speed value update flag (Un\G1181) by using CH1 Measured rotation speed value
update flag reset command (Un\G1170).
If you try to reset it by turning off and on Operating condition settings batch-change command (Y01), not only
the stored value in CH1 Measured rotation speed value update flag (Un\G1181) but also buffer memories for
the data classification Md1 are cleared to 0. Please note that.
(53)CH1 Measured rotation speed value (Un\G1182, Un\G1183)
This memory stores a measured rotation speed value.
The stored value is cleared to 0 by turning off and on Operating condition settings batch-change command
(Y01).
The default value is 0.
(54)CH1 Pulse measurement setting (function input terminal) (Un\G1200)
Use this memory to set which pulse width is to be measured. The pulse is input to the function input terminal
(FUNC1).
The setting value is enabled by turning off and on Operating condition settings batch-change command
(Y01).
The default value is 0
H
: Pulse ON width.
(55)CH1 Pulse measurement setting (latch counter input terminal) (Un\G1201)
Use this memory to set which pulse width is to be measured. The pulse is input to the latch counter input
terminal (LATCH1).
The setting value is enabled by turning off and on Operating condition settings batch-change command
(Y01).
The default value is 0
H
: Pulse ON width.
Pulse width Setting value
Pulse ON width
0
H
Pulse OFF width
1
H
Pulse width Setting value
Pulse ON width
0
H
Pulse OFF width
1
H