(56)CH1 Pulse measurement start command (function input terminal) (Un\G1210)
• When CH1 Count enable command (Y06) is ON, use this memory to start the measurement of pulse that is
input to the function input terminal (FUNC1).
• Set CH1 Pulse measurement start command (function input terminal) (Un\G1210) to 1
H
: Measured to start
the pulse measurement.
• The default value is 0
H
: Not measured.
(57)CH1 Measured pulse value update flag reset command (function input
terminal) (Un\G1211)
• Use this memory to reset CH1 Measured pulse value update flag (function input terminal) (Un\G1221).
• CH1 Measured pulse value update flag (function input terminal) (Un\G1221) is reset by setting CH1
Measured pulse value update flag reset command (function input terminal) (Un\G1211) to 1
H
: Reset. CH1
Measured pulse value update flag reset command (function input terminal) (Un\G1211) is automatically
reset to 0
H
: Not reset after the reset is completed.
• The default value is 0
H
: Not reset.
(58)CH1 Pulse measurement start command (latch counter input terminal)
(Un\G1212)
• When CH1 Count enable command (Y06) is ON, use this memory to start the measurement of pulse that is
input to the latch counter input terminal (LATCH1).
• Set CH1 Pulse measurement start command (latch counter input terminal) (Un\G1212) to 1
H
: Measured to
start the pulse measurement.
• The default value is 0
H
: Not measured.
(59)CH1 Measured pulse value update flag reset command (latch counter input
terminal) (Un\G1213)
• Use this memory to reset CH1 Measured pulse value update flag (latch counter input terminal) (Un\G1241).
• CH1 Measured pulse value update flag (latch counter input terminal) (Un\G1241) is reset by setting CH1
Measured pulse value update flag reset command (latch counter input terminal) (Un\G1213) to 1
H
: Reset.
CH1 Measured pulse value update flag reset command (latch counter input terminal) (Un\G1213) is
automatically reset to 0
H
: Not reset after the reset is completed.
• The default value is 0
H
: Not reset.
(60)CH1 Pulse measurement flag (function input terminal) (Un\G1220)
• This memory stores the value indicating whether the pulse input to the function input terminal (FUNC1) is
being measured.
• When the pulse is being measured, 1
H
is stored. When the pulse is not being measured, 0
H
is stored.
• The stored value is cleared to 0 by turning off and on Operating condition settings batch-change command
(Y01).