Service manual

28
MICROPROCESSOR CONTROL
9
WIRELESS REMOTE CONTROLLER
MCF-13NV - MCF-18NV -
MCF-24NV -
E3
E3E4
MUCF-13NV - MUCF-18NV -
MUCF-24NV -
E3
E3E4
Once the operation mode are set, the same operation mode
can be repeated by simply turning the OPERATE/STOP
(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
9-1. “I FEEL CONTROL” ( )OPERATION
(1) Press OPERATE/STOP button on the remote controller.
Power monitor lamp of the indoor unit will turn on with a
beep tone.
(2) Select “I FEEL CONTROL”( )mode with the OPERA-
TION SELECT button.
(3) The operation mode is determined by the room
temperature at start-up of the operation.
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
STOP
START
HR.
MIN.
I FEEL
COOL
DRY
PM
CLOCK
AM
RESET
CLOCK
FAN
OPERATION SELECT button
FAN SPEED CONTROL button
OFF-TIMER button
HR. button
MIN. button
(TIME SET button)
ON-TIMER button
RESET button
VANE CONTROL button
CLOCK SET button
ON/OFF
TOO
COOL
PM
AM
TOO
WARM
Signal transmitting section
Operation display section
OPERATE /STOP
(ON /OFF)button
TEMPERATURE buttons
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
Once the mode is fixed, the mode will not change by
room temperature afterwards.
Under the ON-TIMER ( )timer operation, the mode
is determined according to the room temperature when
the operation starts.
When the system is stopped with the OPERATE/ STOP
button on the remote controller, and restarted within 2
hours in “I FEEL CONTROL” ( )mode, the system
operates in previous mode automatically regardless of
the room temperature.
Example
Previous operation
COOL mode of “I FEEL
CONTROL” or COOL
mode
When the system is restarted after 2 hours, the operation
mode is determined by the initial room temperature at
start-up of the operation.
Restart
COOL mode of
“I FEEL CONTROL”
Restart
COOL or DRY mode of
“I FEEL CONTROL” that
is determined by initial
room temperature at
start-up of the operation.
INDOOR UNIT DISPLAY SECTION
Initial room temperature mode
more than 25°C
COOL mode of
“I FEEL CONTROL”
13.0°C to 25°C
DRY mode of
“I FEEL CONTROL”
Indication
Operation state
Difference
between set
temperatuer
and room
temperature
This shows that the air
conditioner is operating
to reach the target temp-
erature.
Please wait until the
target temperature is
obtained.
This shows that the
room temperature is
approaching the target
temperature.
About 2
degrees (;)
or more
About 2
degrees (;)
or less
Operation indicator
OB270--1.qxp 4/13/01 2:59 PM Page 28