User`s manual

10 - 24
MELSEC-Q
10. POSITIONING DEBUGGING
Item Description
Step start REQ.
When performing a step start, click the unchecked step start check box.
When you made it valid, choose the step start type.
• Data No. units
Independently of the operation pattern, operation is started from the specified positioning
data No., and is performed and brought to a step standby status per data.
• Deceleration units
When the operation pattern is continuous locus control, test operation is performed up to
continuous positioning control or the last positioning data.
Time
No.1
Continuous
locus control
No.2
Continuous
positioning control
No.3
Continuous
locus control
No.4
End
Step start not made
Deceleration unit step
Data No. unit step
After operation, axis is
brought to step standby.
Speed
After operation, axis is
brought to standby.
"All axis stop" button Click this button to stop all axes.
"Stop" button
Click this button to stop the axis.
Clicking the "Re-start" button resumes test operation from the stop position
<<Feed present value
CHG>> tab
<<Speed CHG>> tab
<<OPR>> tab
<<JOG/MPG>> tab
Click the tab to show the corresponding test screen.
Present value change test .......Refer to Section 10.4.2.
Speed change test...................Refer to Section 10.4.3.
OPR test...................................Refer to Section 10.4.4.
JOG/MPG test..........................Refer to Section 10.4.5.