User`s manual

11 - 28
MELSEC-Q
11. USEFUL FUNCTIONS
11.7.2 Positioning data test edit
PURPOSE
Change the positioning data or block start data in the test mode and write them to
the QD75.
BASIC OPERATION
1. Click unchecked Write data enable flag in Option. (Refer to Section 11.5.)
2. Click the [Online]
[Test]
[Test On/Off] menu (
).
3. The positioning data/block start data edit window appears. (Refer to Section
8.2.1/Section 8.4.1.)
4. Click the [Online]
[Test]
[Edit positioning data] menu (
).
5. Edit the positioning data/block start data. (Refer to Section 8.2.1. / 8.4.1.)
6. Clicking the [Online]
[Test]
[Edit positoning data] menu ( ) shows the
dialog box which confirms whether to write the edited data to the QD75 or not.
7. Click the "OK" button to write to the QD75 the positioning data or block start
data changed in the test mode.
When you click [Cancel], write to QD75 is not performed.
• If the Write data enable flag in Option is not made valid, the data changed or set in
the test mode are not retained.
Make the Write data enable flag invalid when you do not change the positioning
data on the peripheral device.
DISPLAY/SETTING SCREEN
The data changed in the test mode are shown in green letters.