User`s manual

6 - 10
MELSEC-Q
6. PROJECT CREATION
• Since there are no four-axis type AD75 positioning modules, the positioning data,
block start data and parameters of the fourth axis are not read if the QD75 model
of the save destination project is of the four axis type.
• Note the following when the file in the SW1IVD-AD75P-E or SW0D5C-AD75P-E
format has been read.
Data Type Read to SW D5C-QD75P-E
Start bias speed
Section is changed from basic parameter
2 to basic parameter 1
MPG
Over limit switch
Under limit switch
Drive unit ready
Stop signal
External signal
Zero phase signal
Zeroing dog
MPG
DCC
These are new items and therefore not
read. Default setting.
Output
pulse logic
selection
Command pls
signal
This name has been changed from the
pulse output logic selection to the drive
unit.
Stepping motor mode selection
Manual pulse generator
selection
ACC/DEC time unit selection
These are disused items and therefore
read-disabled.
Near path control mode
These are disused items and therefore
read-disabled. (Because near path
control mode is fixed)
MPG mode
Parameter
Speed-position function selection
This is a new item and therefore read-
disabled. Default setting.
SLV axis
This is a new item and therefore read-
disabled. Default setting.
Positioning
data
Positioning comment Not read from SW1IVD-AD75P-E.
Block start data
This name has been changed from the
start block data.
Because of reduction in number of
blocks, block numbers 5 to 10 are read-
disabled.
"Stop" in special start is replaced by
"Wait start".
Indirect Data
This is a disused item and therefore
read-disabled.
: After file reading, condition data setting is needed.