User`s manual

8 - 3
MELSEC-Q
8. DATA SETTING
8.2 Positioning Data Setting
This section describes the positioning data setting, the addition of circular interpolation
control to the positioning data by specifying a sub point, and speed setting using the
axis speed calculation function.
This section also explains the M code comment setting in which the M codes assigned
to the positioning data are annotated with comments.
8.2.1 Positioning data
PURPOSE
Set the positioning data such as the operation pattern, control method, SLV axis,
acceleration time No., deceleration time No., address and command speed.
For details of the positioning data, refer to QD75 User's Manual.
BASIC OPERATION
1. Choose the axis to which the positioning data will be set.
Double click
Double click
2. Set the data in the positioning data edit window.
DISPLAY/SETTING SCREEN
Double-click the cell and make setting in the text box or list box.
For "SLV axis", choose it from the SLV axis set dialog box when the control
method is 2-axis interpolation control.
When performing operation from the keyboard, enter the value and press the
"Enter" key to determine the value.
For "Pattern', "CTRL method", "ACC" and "DEC", press the "space" key to display
a list.
Make selection with the "
" or " " key, and press the "Enter" key to determine the
value.