8. DATA SETTING
[Locus data for 2-axis interpolation control]
DISPLAY/SETTING DATA
Item Description
Positioning start No.
Set the first positioning data No. from which simulation starts.
Simulation is performed on the data from the specified No. to the "End" of the operation
pattern.
Scaling
Used to enlarge or reduce the simulation result in the vertical and horizontal directions.
Moving the side to the right enlarges the result.
"Fixed ratio" check box
Click the unchecked check box to enlarge/reduce the result in the vertical and horizontal
directions by the same ratio.
Time/Speed
(Waveform data)
Shows the time and axis speed at the position clicked in the simulation result display.
#1 to #4 axis coordinates
(Locus data)
Shows the coordinates at the position clicked in the simulation result display.
In the screen example, the coordinates shown are those of Axis #1 used as the reference
axis and Axis #2 used as the interpolation axis.
Simulation result
Shows the simulation result.
Changing the positioning data also changes the simulation result in synchronization.
For 2-axis interpolation control, the reference axis is in the horizontal direction and the
interpolation axis is in the vertical direction.
For 1-axis control, time is in the horizontal direction and the axis speed is in the vertical
direction.
Use the scroll bars to move the display area.