Specifications

2
2. OPERATION
2 25
This mode cannot be used for the absolute position detection system.
Set parameter No. 1 to select the incremental positioning system.
MEMORANDUM
(3) Test operation mode
1) Jog feed
Jog feed can be performed without pulse train input from acommand unit or the like.
b. Starting method
Perform the following operation to rotate the servo motor at 200r/min.At this time, the
acceleration/deceleration time constant is 1s. Whenperforming jog feed, connect EMG-
SG and VDD-COM (when internal power supply is used).
a. Mode change
Call the display screen shown after power-on.
UP
DOWN
Rotation
Direction
CCW
CW
Operation
Press
Press
To stop, release the corresponding button.
c. Status display
Press
MODE
to display the servo status during test operation. The display data is the
same as in the status display in Section 2-3-2.
d. Termination of jog feed
To terminate the jog feed, switch power off once or call the screen using
MODE
and press
SET
for more than 2s.
CAUTION
Press UP three times.
When this screen appears, jog feed can be performed.
•••••
Flickers in the test operation mode.
Press MODE once.
Press SET for more than 2 seconds.
1. The test operation mode is designed to confirm servo operation and
not to confirm machine operation. In this mode, do not use the servo
motor with the machine. Always use the servo motor alone.
2. If any operational fault has occurred, stop operation using the emer-
gency stop (EMG) signal.