Specifications

2. OPERATION
2 44
29
VCO
Analog speed command offset:
Used to set the offset voltage of the analog speed
command (VC). When automatic VC offset is used, the
automatically offset value is set to this parameter.
(See section 2-3-3.)
The initial value is the value provided by the automatic VC
offset function before shipment at the VC-LG voltage of 0V.
Depends
on servo
amplifier.
999 to 999
S
mV
Analog speed limit offset:
Used to set the offset voltage of the analog speed limit
(VLA). When automatic VC offset is used, the auto-
matically offset value is set to this parameter.
(See section 2-3-3.)
The initial value is the value provided by the automatic VC
offset function before shipment at the VLA-LG voltage of 0V.
T
30
TLO
Analog torque command offset:
Used to set the offset voltage of the analog torque
command (TC).
0
999 to 999
T
mV
Analog torque limit offset:
Used to set the offset voltage of the analog torque limit
(TLA).
S
31
MO1
Analog monitor 1 offset:
Used to set the offset voltage of the analog monitor 1
output (MO1).
0
999 to 999
P S T
mV
32
MO2
Analog monitor 2 offset:
Used to set the offset voltage of the analog monitor 2
output (MO2).
0
999 to 999
mV
33
MBR
Electromagnetic brake sequence output:
Used to set the delay time between when the electro-
magnetic brake interlock signal (MBR) switches off and
when the base circuit is shut off.
100
0
to
1000
ms
P S T
34
GD2
Ratio of load inertia moment to servo motor inertia moment:
Used to set the ratio of the load inertia moment to
the servo motor inertia moment. Note that when auto
tuning is selected, the result of auto tuning is auto-
matically set.
70
0 to 1000
0.1 times
P S
35
PG2
Position loop gain 2:
Used to set the gain of the position loop.
Set this parameter to increase position response to
load disturbance. Higher setting increases the response
level but is liable to generate vibration and/or noise.
30
1
to
500
rad/s
P
36
VG1
Speed loop gain 1:
Normally this parameter setting need not be changed.
Higher setting increases the response level but is liable
to generate vibration and/or noise.
216
20
to
5000
rad/s
P S
37
VG2
Speed loop gain 2:
Set this parameter when vibration occurs on machines of
low rigidity or large backlash. Higher setting increases the
response level but is liable to generate vibration and/or noise
.
714
20
to
8000
rad/s
P S
Class No.
Symbol
Initial
Value
Unit
Setting
Range
Control
Mode
Name and Function
Expansion parameters